| 2005-01-14 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 04120964 |
| | ADD: 5705 S DIXIE BAY H" |
| | CONT: SUNDOWN |
| | TEL: (561)743-4420 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | |
| | 1) CONTACT JOHN HIGINS @ (561)822-1239 |
| | TO CORRECT ADDRESS. CITY INDICATES 5705 |
| | S DIXIE NOT 5707. |
| | 1A) BAYS TO HAVE NUMERIC FIGURES. |
| | |
| | 2) PROVIDE NOC RECORDED WITH THE CLERK |
| | OF COURT BEFORE A PERMIT CAN BE ISSUED. |
| | |
| | 3) MISSING EXIT SIGN FRONT OF BUILD |
| | OUT. |
| | 1016.3.1. EXIT SIGNS: |
| | EXIT SIGNS SHALL BE MARKED BY AN |
| | APPROVED SIGN READILY VISIBLE FROM ANY |
| | DIRECTION OF EXIT ACCESS. EVERY EXIT |
| | SIGN SHALL BE SUITABLE ILLUMINATED BY A |
| | RELIABLE LIGHT SOURCE. EXTERNALLY AND |
| | INTERNALLY ILLUMINATED SIGNS SHALL BE |
| | VISIBLE IN BOTH THE NORMAL & EMERGENCY |
| | LIGHTING. |
| | |
| | 4) FL BLD CODE CHAP 13 ENERGY EFFICENCY |
| | PROVIDE ENERGY CALS/ W MANUAL "J" |
| | |
| | 5) 1511.7 ROOF MOUNTED MECHANICAL UNIT S |
| | SHALL BE MOUNTED ON CURBS RAISED A |
| | MINIMUM OF 8 INCHES ABOVE THE ROOF SUR- |
| | FACE, OR WHERE ROOFING MATERIALS EXTEND |
| | BENEATH THE UNIT, ON RAISED EQUIPMENT |
| | SUPPORTS PROVIDING A MINIMUM CLEARENCE |
| | HEIGHT IN ACCORDANCE WITH TABLE 1511.7. |
| | MECH. 301.13 WIND RESISTANCE MECHANICAL |
| | EQUIPMENT, APPLIANCES AND SUP PORTS THAT |
| | ARE EXPOSED TO WIND SHALL BE DESIGNED |
| | AND INSTALLED TO RESIST THE WIND |
| | PRESSURES ON THE EQUIPMENT & THE |
| | SUPPORTS AS DETERMINED IN ACCORDANCE |
| | WITH THE FL BLD CODE. THIS MAY BE ACCOMP |
| | LISHED BY DESIGN OR BY APPLICATION OF |
| | SECTION 301.13.1. |
| | |
| | 60 704.2.1.4 CORRIDOR PARTITIONS, |
| | SMOKE STOP PARTITIONS, HORIZONTAL EXIT |
| | PART- ITIONS, EXIT ENCLOSURES, AND FIRE |
| | RATED WALLS REQUIRED TO HAVE PROTECTED |
| | OPENINGS SHALL BE EFFECTIVELY AND |
| | PERMANETLY IDENTIFIED WITH SIGNS OR |
| | STENCILING IN A MANNER ACCEPTABLE TO THE |
| | AUTHORITY HAVING JURISDICTION. SUCH IDEN |
| | TIFICATION SHALL BE ABOVE ANY DECORATIVE |
| | CEILING CEILING AND IN CONCEALED SPACES. |
| | SUGGESTED WORDING" FIRE & SMOKE BARRIER |
| | PROTECT ALL OPENINGS". |
| | |