2005-01-24 00:00:00DENIED:
 1.ENERGY CALCULATIONS FOR MODEL A & C
 INDICATE MULTI-FAMILY.ENERGY
 CALCULATIONS FOR A UNIT SHOWS SINGLE
 FAMILY.PLEASE CLARIFY.SEE ALSO
 COMMENT #1 BY JIM WITMER, BUILDING PLAN
 REVIEW.
  
 2.PROVIDE OUTSIDE AIR CALCULATIONS IN
 ACCORDANCE WITH 2001 FBC(M)402.2 &
 402.2.1 OR TABLE 403.3.
  
 3.AHU'S SHALL BE A MINIMUM OF 4"
 CLEARANCE AROUND UNIT FOR CONSTRUCTION,
 SEALING INSPECTION AND MAINTENANCE.
  
 4.DRYER EXHAUST TERMINATION SHALL BE
 NOON-SCREENED AND EQUIPPED WITH A
 BACKDRAFT DAMPER.
  