| 2005-02-28 00:00:00 | DENIED |
| | |
| | 1) THE STRUCTURE IS LOCATED IN AN "A5" |
| | FLOOD ZONE AN ELEVATION CERTIFICATE WILL |
| | BE REQUIRED. |
| | |
| | 2) SHOP DRAWINGS WILL BE REQUIRED TO BE |
| | SUBMITTED FOR THE ALUMNIUM GUARDRAILS. |
| | |
| | 3)PRODUCT APPROVALS SUBMITTED |
| | WITH PERMIT APPLICATION AFTER OCTOBER 1, |
| | 2003 ARE REQUIRED TO COMPLY WITH THE |
| | FLORIDA PRODUCT APPROVAL SYSTEM. FOR |
| | INFORMATION PLEASE SEE THE STATE WEBSITE |
| | AT WWW.FLORIDABUILDING.ORG. PRODUCTS |
| | WITH STATEWIDE APPROVAL ARE REQUIRED TO |
| | BE SUBMITTED WITH A COVER SHEET THAT |
| | LISTS THE PRODUCT IDENTITY NUMBER FROM |
| | THE STATE. IF THE PRODUCT DOES NOT HAVE |
| | STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| | TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| | SPECIFIC FORM PER RULE 9B-72. |
| | A COVER SHEET WITH THE FL PRODUCT |
| | APPROVAL NUMBER IS REQUIRED TO BE |
| | ATTACHED TO THE MATCHING INSTALLATION |
| | INSTRUCTIONS (NOA, ICC EVALUATION |
| | REPORT, OR ENGINEERING) FOR ALL WINDOWS, |
| | DOORS AND OTHER STRUCTURAL COMPONENTS |
| | LISTED IN F.A.C. RULE 9B-72. |
| | |
| | 4) SUBMIT FL PRODUCT APPROVAL COVER |
| | SHEETS FOR THE MULLIONS,SWD-101 FRENCH |
| | DOOR, FD-101 FRENCH DOOR WITH SIDELITE, |
| | SH-701 SINGLE HUNG WINDOWS AND METAL |
| | ROOF SYSTEM. |
| | |
| | 5) A PRODUCT APPROVAL FOR NON-IMPACT |
| | CASEMENT WINDOWS WAS SUBMITTED. SUBMIT |
| | STORM PANEL PRODUCT APPROVALS, KEY PLAN |
| | AND INSTALLATION SCHEDULE FOR THESE |
| | WINDOWS. PLEASE REMOVE FROM SUBMITTALS |
| | IF THESE WINDOWS ARE NOT BEING |
| | INSTALLED. |
| | |
| | 6) THE STATE PRODUCT APPROVAL COVER |
| | SHEET FOR FD-750 DOORS WERE SUBMITTED |
| | WITHOUT THE INSTALLATION INSTRUCTIONS, |
| | NOA OR OTHER EVALUATION. PLEASE CORRECT. |
| | |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |
| | (561)805-6714 |