| Date |
Text |
| 2005-03-01 00:00:00 | DENIED |
| | REFERENCE: FBC-2001 CHAPTER 1 |
| | FBC-2001 CHAPTER 11 |
| | |
| | FROM PREVIOUS REVIEW: |
| | SUBMIT A DETAIL FOR THE KITCHEN SINK |
| | SHOWING COMPLIANCE WITH THE FOLLOWING: |
| | A) KNEE CLEARANCE 11-4.24.3 |
| | B) SINK DEPTH 11-4.24.4 |
| | C) CLEAR FLOOR SPACE 11-4.24.5 (THE |
| | CLEAR FLOOR SPACE SHALL BE PROVIDED IN |
| | FRONT OF A SINK TO ALLOW FORWARD |
| | APPROACH. THE CLEAR FLOOR SPACE SHALL BE |
| | ON AN ACCESSIBLE ROUTE AND SHALL EXTEND |
| | A MAXIMUM OF 19" UNDERNEATH THE SINK). |
| | (SEE FIGURE 32). PARALLEL APPROACH IS |
| | NOT APPROVED. |
| | D) EXPOSED PIPES AND SURFACES 11-4.24.6 |
| | E) FAUCETS 11-4.24.7 |
| | *****THIS INFORMATION SHALL BE INCLUDED |
| | ON THE PLANS. SUCH INFORMATION SHALL BE |
| | SPECIFIC, AND THE TECHNICAL CODES SHALL |
| | NOT BE CITED AS A WHOLE OR IN PART, NOR |
| | SHALL THE TERM "LEGAL" OR ITS EQUIVALENT |
| | BE USED AS A SUBSTITUTE FOR SPECIFIC |
| | INFORMATION. SECTION 104.2.1.***** |
| | 2) SUBMIT A DETAIL FOR THE TOILET ROOMS |
| | SHOWING THE FOLLOWING INFORMATION: |
| | B) TOILET TO BE 18" OFF THE WALL TO THE |
| | CENTERLINE OF THE FIXTURE. FIG. 28 |
| | D) GRAB BARS 11-4.16.4 GRAB BARS FOR |
| | WATER CLOSETS NOT LOCATED IN STALLS |
| | SHALL COMPLY WITH 11-4.26 AND FIGURE 29. |
| | FLOOR MOUNTED GRAB BARS ARE NOT APPROVED |
| | PER THIS SECTION OF THE CODE. |
| | E) FLUSH CONTROLS 11-4.16.5 - NO |
| | RESPONSE TO THIS REQUEST NOTED. |
| | G) EXPOSED PIPES & SURFACES 11-4.19.4 - |
| | NO RESPONSE TO THIS REQUEST NOTED. |
| | H) FAUCET 11-4.19.5 |
| | *************NEW COMMENT********* |
| | SEE SHEET CONCERNING DESIGN PROFESSIONAL |
| | AND FLA. STATUTE 553.80(2)(B) SUBMITTED |
| | BY THE STRUCTURAL PLAN REVIEWER. |
| | |
| | REVIEW BY KEN STEVENS |
| | (561) 805-6721 |
| | FAX (561) 653-2692 |
| | E-MAIL [email protected] |