| 2004-12-13 00:00:00 | BUILDING PLAN REVIEW: FAILED | | | | | | 1. APPLICATION STATES PGT SASH & | | | CASEMENT WINDOWS TO BE INSTALLED IN | | | PLACE OF AWNING WINDOWS.PRODUCT | | | APPROVALS SUBMITTED ARE FOR SINGLE HUNG | | | WINDOWS. | | | | | | 2. FOOTPRINT OF HOUSE MUST SHOW EACH | | | OPENING, SIZE OF OPENING & TYPE OF | | | WINDOW TO BE INSTALLED. ALSO SHOW | | | LOCATION OF BEDROOMS TO VERIFY | | | COMPLIANCE WITH FBC2001 MEANS OF | | | EGRESS. | | | | | | 3. HOW MANY WINDOWS ARE BEING REPLACED? | | | FBC2001 STATES THAT IF MORE THAN 25% OF | | | GLASS AREA IS BEING REPLACED HURRICANE | | | PROTECTION MUST BE INSTALLED. | | | | | | 4. ALL SUBMITTALS MUST BE IN DUPLICATE. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|