| 2006-08-23 00:00:00 | 1. SUBMITTAL #15047.01 PIPE |
| | IDENTIFICATION AND VALVE TAGS (OK) |
| | 2. SUBMITTAL #15181.01 CRETE SLEEVES |
| | (OK) |
| | 3. SUBMITTAL #15400.04 WASHING MACHINE |
| | BOX (OK) |
| | 4. SUBMITTAL #15410.04 DUTCH BOY SOLDER |
| | MSDS SHEETS (OK) |
| | 5. SUBMITTAL #15410.05 SOLDER PASTE FLUX |
| | (DENIED) |
| | A) THE SUBMITTAL FOR OATLY PASTE FLUX |
| | #5 DOES NOT SHOW COMPLIANCE FBC-2004, |
| | PLUMBING, SECTION 605.14.3 AND 605.15.4 |
| | FLUX CONFORMING TO ASTM B 813 SHALL BE |
| | APPLIED, PLEASE SUBMIT MANUFACTURER |
| | SHEET FOR SAID SUBMITTAL CONFORMING TO |
| | ASTM B 813 OR PLEASE SUBMIT ANOTHER. |
| | 6. SUBMITTAL #15430.07 HOSE BIBBS (OK) |
| | 7. SUBMITTAL #15430.08 TRAP PRIMERS AND |
| | WATER ARRESTERS (OK) |
| | "EXCEPTION" |
| | A)SEMI CAST TRAP PRIMER TLPC (DENIED) |
| | MORE INFORMATION REQUIRED, PLEASE SUBMIT |
| | MANUFACTURER SHEETS WITH SAID SUBMITTAL |
| | CONFORMING TO FBC-2004 PLUMBING, CHAPTER |
| | 10. |
| | 8. SUBMITTAL #15455.02 DRAINAGE PIPE AND |
| | FITTINGS (OK) |
| | 9. SUBMITTAL #15455.03 VENT THROUGH ROOF |
| | FLASHINGS (OK) |
| | 10. SUBMITTAL #15484.01 OATLY CHEMICALS |
| | MSDS SHEETS (OK) |
| | 11. SUBMITTAL #15484.03 HERCULES PIPE |
| | DOPE (OK) |
| | 12. SUBMITTAL #15499.01 PLUMBING PIPE |
| | INSULATION (OK) |
| | |