| 2005-01-04 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT:04111389 |
| | ADD: 1661 WORHTINGTON RD |
| | CONT: LEIGHTON MCGINN |
| | TEL: (561)767-7521 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 1STREVIEW |
| | ACTION: DENIED |
| | |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL |
| | LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT |
| | NUM- |
| | BER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR |
| | SPECIFICA |
| | TION PAGE WHERE THE CHANGES CAN BE |
| | FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. |
| | THANK |
| | YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | |
| | 1)PROVIDE NOC RECORDED WITH THE CLERK |
| | OF |
| | COURT BEFORE A PERMIT CAN BE ISSUED. |
| | |
| | 2) SHEET SP-1 BUILDING DATAINDICATES |
| | A |
| | FACTORY/ INDUSTRIAL USAGE, WHAT WILL BE |
| | MANUFACTURED? |
| | 2A) IF THE USAGE WILL BE OFFICES THEN |
| | THE OCCUPANCY WILL BE CONSIDERED |
| | BUSINESS, THE PLAN NEED TO REFLECT |
| | THIS. |
| | THIS RECLASSIFICATION MAY RESULT IN |
| | ADDITIONAL FEES: |
| | (1) COUNTY IMPACT FEES |
| | (2) ADDITIONAL PERMIT FEES TO THE |
| | SHELL AND TENANT BUILD OUT. |
| | |
| | 3) PROVIDE ENERGY CALCULATIONS AND |
| | EQUIPMENT SIZING CALCULATIONS (MANUAL |
| | J) |
| | AS REQUIRED BY THE 2001 FLORIDA ENERGY |
| | EFFICIENTCY CODE FOR BUILDING CONSTRUC- |
| | TION. |
| | |
| | 4) FBC 13-103.1.2 BEFORE A BUILDING |
| | PERMIT CAN BE ISSUED, THE SUBMITTED |
| | ENERGY CODE COMPLIANCE FORMS SHALL BE |
| | SIGNED BY THE BUILDING OWNER, THE |
| | OWNER'S ARCHETECT OR OTHER AUTHORIZED |
| | AGENT LEGALLY DESIGNATED BY THE OWNER. |
| | |
| | 5) CORRECTION, CODE REFRENCE, SEE A-3 |
| | NOTE# 3, REFRENCE TO THE S.F.B.C. |
| | |
| | 6) A2.4 BOARDROOM 768 SQ FT/ 52 OCC |
| | LOAD, 1004.1.2 > 50 OCCUPANT LOAD |
| | REQUIRES 2 EGRESSES, 1/3 DIAGONALL FOR |
| | FIRE SPRINKLERED BUILDINGS. |
| | |
| | 7) A2.4 DETAIL OF ANTEROOM SINK TO |
| | COMPLY WITH:11-4.24.2 SINKS, HEIGHT. |
| | SINKS SHALL BE MOUNTED WITH THE COUNTER |
| | NO HIGHER THAN 34" ABOVE THE FINISH |
| | FLOOR. |
| | 11-4.24.3 KNEE CLEARENCE THAT IS AT |
| | LEAST 27" HIGH 30" WIDE, AND 19" DEEP |
| | SHALL BE PROVIDED UNDERNEATH SINKS. |
| | |
| | 8) FL BLD CODE 104.2.1.2* |
| | ADDITIONAL INFORMATION REQUIRED, A2.4 |
| | THE BOARDROOM DETAILS INDICATE THE USE |
| | OF GYPSUM BOARD SOFFITS, PROVIDE |
| | DETAILS |
| | |
| | GYPSUM THICKNESS, STUD SIZE &SPACING |
| | DETAILS HOW TOATTACH TO STRUCTURE |
| | ABOVE. |
| | |
| | 9)FL BLD CODE 104.2.1.2* |
| | ADDITIONAL INFORMATION REQUIRED, |
| | A-1.8 PROVIDE THE WIDTH OF THE AISLE |
| | DIRECTLY IN FRONT OF OFFICE# 175? |
| | |
| | 10) A-1.8 THE DOOR LEADING INTO |
| | CORRIDOR |
| | 171 SWINGS AGAINST THE PATH OF EXITING |
| | SEE 1012.1.2 DOORS TO SWING IN THE |
| | EXITINGWHEN > 50 OCC LOAD. |
| | |
| | 11) A-1.8 IT APPEARS THAT THERE IS SOME |
| | "BOTTLENECKING" WITH THE DOORS LEADING |
| | TO THE CORRIDOR AND VESTIBULE. SEE |
| | 1003,2,3,2, ALSO PROVIDE A LIFE SAFETY |
| | PLAN. |
| | |
| | 12) FL BLD CODE 104.2.1.2 |
| | ADDITIONAL INFORMATION REQUIRED, SEE |
| | E3.3 DETAIL FOR THE RAISED FLOOR, |
| | 12A) PROVIDE THE LOCATION OF WHICH ROOMS |
| | WILL HAVE THE RAISED FLOOR? |
| | 12A) WHAT MATERIALS WILL BE FOR THE |
| | FRAMING AND FLOOR? |
| | 12B) INDICATE CONFORMANCE WITH |
| | ACCESSIBILITY RAMPS: |
| | 12C) 11-4.8.2 SLOPE & RISE. THE LEAST |
| | POSSIBLE SLOPE SHALL BE USED FOR ANY |
| | RAMP. THE MAXIMUM SLOPE FOR A RAMP IN |
| | NEW CONSTRUCTION SHALL BE 1 TO 12. THE |
| | MAXIMUM RISE FOR RUN SHALL BE 30" (SEE |
| | FIGURE 16). |
| | 12D) 11-4.8.3. CLEAR WIDTH. THE MINIMUM |
| | CLEAR WIDTH OF A RAMP SHALL BE 36". |
| | EXCEPTION: RAMPS THAT ARE PART OF A |
| | REQUIRED MEANS OF EGRESS SHALL NOT BE |
| | LESS THAN 44 INCHES WIDE. |
| | 12E) 11-4.8.4.(2) LANDINGS. ALL LANDINGS |
| | ON RAMPS SHALL NOT BE LESS THAN 60" |
| | CLEAR, & THE BOTTOM OF EACH RAMP SHALL |
| | HAVE NOT LESS THAN 72" OF STRAIGHT & |
| | LEVEL CLEARENCE. |
| | 12F) 11.4.8.5. HANDRAILS: IF A RAMP HAS |
| | A RISE GREATER THAN 6" OR A HORIZONTAL |
| | PROJECTION GREATER THAN 72", THEN IT |
| | SHALL HAVE HANDRAILS ON BOTH SIDES. |
| | |
| | 13) E5.1 INDICATES THE USE OF |
| | BATTERIES, |
| | PROVIDE INFORMATION SHOWING COMPLIANCE |
| | WITH 308.2(9) H-4 OCCUPANCY. |
| | |
| | 14) E5.1ALSO INDICATES THE USE OF A |
| | GENERATOR AND FUEL TANK, THE SITE PLAN |
| | DOES NOT INDICATE LOCATION? |
| | |
| | 15) M7.2 HVAC UNIT DETAIL HANGS THE UNIT |
| | FROM THE BOTTOM OF THE BAR JOIST, |
| | PROVIDE ENGINEER OF RECORD THAT THIS |
| | DESIGN WILL BE ACCEPTABLE. |
| | |
| | 16) FL BLD CODE 104.2.1.2 |
| | ADDITIONAL INFORMATION REQUIRED, |
| | WILL THERE BE ANY ELECTRIC LOCKS ON THE |
| | EXTERIOR DOORS, THERE IS NO INDICATION? |
| | |
| | 17) BEFORE A PERMIT TO CONSTRUCT, MAY BE |
| | ISSUED, IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY. THE ACTUAL PERMIT |
| | SET OF PLANS MUST BE STAMPED BY THAT |
| | OFFICE, AND A COPY OF THE PAID RECEIPT |
| | ATTACHED TO THE PERMIT APPLICATION. |
| | PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | BUILDING PLAN REVIEW |
| | JIM WITMER |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |