Plan Review Notes
Plan Review Notes For Permit 04110961
Permit Number 04110961
Review Stop B
Sequence Number 2
Notes
Date Text
2005-03-18 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
 F.S.= FLORIDA (STATE) STATUTE
  
 FOR CONSISTENCY, THE FOLLOWING COMMENTS
 ARE NUMBERED AS PER THE BUILDING PLAN
 REVIEW OF 1/11/05:
  
 2) NOTE THAT THE NOTICE OF
 COMMENCEMENT, IMPACT FEE RECEIPT AND
 SPECIAL INSPECTOR AGREEMENT WILL BE
 REQUIRED BEFORE A PERMIT CAN BE ISSUED.
 ALSO A DECLARATION OF CONDOMINIUM WILL
 BE REQUIRED BEFORE CERTIFICATE OF
 OCCUPANCY.
  
 7) FBC 13-103.1.2BEFORE A BUILDING
 PERMIT CAN BE ISSUED, THE SUBMITTED
 ENERGY CODE COMPLIANCE FORMS SHALL BE
 SIGNED BY THE BUILDING OWNER, THE
 OWNER'S ARCHITECT OR OTHER AUTHORIZED
 AGENT LEGALLY DESIGNATED BY THE OWNER.
  
 8) PRODUCT APPROVALS.THE REQUIRED
 STATEWIDE PRODUCT APPROVAL LISTINGS HAVE
 BEEN PRINTED AND ATTACHED TO ONE OF THE
 THREE SUBMITTED PRODUCT APPROVAL SETS.
 THIS WILL SERVE AS AN EXAMPLE OF WHAT IS
 REQUIRED FOR ALL THREE SETS AND TO
 ADDRESS THE COMMENTS BELOW:
 (A) SOME THE OPTIONS COVERED BY THE
 SUBMITTED PRODUCT APPROVALS MAY NOT BE
 CODE COMPLIANT IF USED FOR THIS
 PROJECT/LOCATION.FOR EACH PRODUCT
 APPROVAL, THESHEETS SHALL BE MARKED,
 AS APPROPRIATE, TO IDENTIFY WHICH
 PRODUCT
 OPTIONS/MATERIALS/SIZES ARE TO BE USED.
 THIS APPLIES ALSO TO THE FLAT ROOFING
 PRODUCT APPROVAL WHICH IS 48 PAGES LONG
 COVERING MANY DIFFERENT SYSTEMS, PLEASE
 SELECT ONE (SEE COMMENT 8B FIRST).
 (B) THE SUBMITTED FIRESTONE PRODUCT
 APPROVAL NOA# 01-0424.04 IS FOR A
 MODIFIED BITUMEN ROOF SYSTEM.THIS DOES
 NOT CORRELATE WITH THE PLANS (SHEETS
 A5-4, A7-2, A7-5 AND A8.1 FOR EXAMPLE)
 WHICH SPECIFY A 4 PLY BUILT UP ROOF
 SYSTEM.SUBMIT AN ALTERNATIVE PRODUCT
 APPROVAL OR AMEND THE PLANS TO SPECIFY A
 A ROOF SYSTEM THAT CORRESPONDS TO THE
 SUBMITTED PRODUCT APPROVAL.
 (C) THE WINDOW WALLS SHOWN ON SHEET
 A3-3HAVE FRAME HEIGHTS OF 15'-5" AND
 17'-4".THESE DIMENSIONS ARE OUTSIDE
 THE SCOPE OF THE SUBMITTED R.C. ALUMINUM
 SERIES FX345 AND HP3060 PRODUCT APPROVAL
 NOA#'S 04-830.02 AND 03-1224.04.SUBMIT
 ALTERNATIVE PRODUCT APPROVALS TO COVER
 THE REQUIRED SIZES OF WINDOW WALL.
 (D) THE SUBMITTED R.C. ALUMINUM
 SLIDING GLASS DOOR PRODUCT APPROVAL NOA#
 02-0222.04 GIVES A MAXIMUM DESIGN
 PRESSURE OF -108.1 PSF FOR A 10'M HIGH
 PANEL OVER 3'-6" WIDE.THIS IS EXCEEDED
 BY THE -115 PSF REQUIRED BY THE RWDI
 WIND TUNNEL REPORT FIG. 5 (PHASE I,
 NORTH ELEVATION, NEGATIVE PRESSURES).
 SUBMIT AN ATERNATIVE PRODUCT APPROVAL
 WITH ADEQUATE ALLOWABLE DESIGN PRESSURE
 FOR THE DOORS IN THIS LOCATION.
 (E) SUBMIT PRODUCT APPROVALS FOR THE
 PARKING GARAGE DOOR #25, AND FOR THE
 STOREFRONT DOORS THAT ARE LARGER THAN
 THE 6070 SIZE LIMIT OF THE SUBMITTED
 FIREDOOR LLC PRODUCT APPROVAL (E.G.
 DOORS 01, 02, 45, 46, 47 AND 87)
 (F) FL. ADMIN CODE RULE 9B-72.A
 SEARCH AT THE DEPT OF COMMUNITY AFFAIRS
 PRODUCT APPROVAL WEBSITE
 WWW.FLORIDABUILDING.ORG/PR/PR_SRCH.ASP
 SHOWS NO MATCHING STATEWIDE PRODUCT
 APPROVAL FOR THE SUBMITTED DIXIE METAL
 PRODUCTS, INC ALUMINUM RAILING SYSTEM
 (PRODUCT APPROVAL NOA# 01-0206.14).IF
 CUSTOM GUARDRAILS ARE USED THEY CAN BE
 ENGINEERED AS SITE SPECIFIC INSTEAD.IF
 A MODULAR SYSTEM (SUCH AS THE ONE
 PROPOSED) IS TO BE USED, THE SYSTEM MUST
 HAVE STATEWIDE OR LOCAL PRODUCT
 APPROVAL.
 NOTE: FL. ADMIN CODE RULE 9B-72 (IN
 EFFECT SINCE OCTOBER 1, 2003) REQUIRES
 THAT PRODUCTS HAVE STATEWIDE, LOCAL OR
 SITE-SPECIFIC PRODUCT APPROVAL.THE
 SUBMITTAL SHOULD INCLUDE THE STATEWIDE
 PRODUCT APPROVAL NUMBER (FL###),
 AVAILABLE FROM THE DEPT OF COMMUNITY
 AFFAIRS PRODUCT APPROVAL WEBSITE
 WWW.FLORIDABUILDING.ORG/PR/PR_SRCH.ASP
 (IF YOU FIND THAT THE QUOTED WEB PAGE IS
 NO LONGER AVAILABLE, PLEASE INFORM THE
 PLAN REVIEWER)
 (G) PRODUCT APPROVAL ADVICE.
 RULE 9B-72 FAC. FOR PRODUCTS WHICH DO
 NOT HAVE STATEWIDE PRODUCT APPROVAL,
 LOCAL PRODUCT APPROVAL CAN BE ACHIEVED
 IF THERE IS A QUALITY ASSURANCE PROGRAM
 IN PLACE WITH A STATE APPROVED QUALITY
 ASSURANCE ENTITY.LOCAL PRODUCT
 APPROVAL WILL ALLOW A PRODUCT TO BE
 USED, IN ACCORDANCE WITH THE TEST
 CRITERIA, THROUGHOUT THE JURISDICTION OF
 WEST PALM BEACH. LOCAL PRODUCT APPROVAL
 APPLICATION FORMS ARE AVAILABLE FROM
 THIS OFFICE. APPROVED QUALITY ASSURANCE
 ENTITIES ARE LISTED ON THE DCA WEBSITE:
 WWW.FLORIDABUILDING.ORG/COMMON/C_ORG_
 REGI_SRCH.ASP (IF YOU FIND THAT THE
 QUOTED WEB PAGE IS NO LONGER AVAILABLE,
 PLEASE INFORM THE PLAN REVIEWER)
  
 12) FBC 411.2.3SHEET S-1.06 SPECIFIES
 WALL TYPE TW-1 AS VEHICLE IMPACT
 GUARDING ALONG GRID P.H. BUT THE WALL
 SCHEDULE ON SHEET S-4.2 DOES NOT SHOW A
 WALL TYPE TW-1.SPECIFY A DIFFERENT
 WALL TYPE OR PROVIDE DETAILS OF WALL
 TYPE TW-1.
  
 16) SHEET A3-1, DOOR SCHEDULE.DOORS
 43, 45 AND 47 ON SHEET A1-9 AND DOOR 121
 ON SHEET A1-13 ARE SHOWN AS DOUBLE
 DOORS, BUT THESE ARE CALLED UP AS SINGLE
 DOORS ON THE DOOR SCHEDULE.ALSO THE
 SUBMITTED LOUVER DOOR PRODUCT APPROVAL
 IS NOT CALLED UP ON THE DOOR SCHEDULE
 FOR ANY EXTERIOR USE APPLICATION.IF NO
 EXTERIOR LOUVER DOORS ARE PROPOSED, THE
 LOUVER DOOR PRODUCT APPROVAL IS NOT
 REQUIRED.PLEASE CLARIFY.
  
 18) FBC 1003.1SHEET A0-3, OCCUPANT
 LOAD.THIS COMMENT HAS NOT BEEN
 PROPERLY ADDRESSED.THE PLANS SHALL
 STATE THE NUMBER OF OCCUPANTS FOR EACH
 SPACE TO FACILITATE VERIFICATION OF
 ADEQUATE EGRESS/EXIT PROVISION.FOR
 EXAMPLE, WHAT IS THE NUMBER OF OCCUPANTS
 IN THE CLUB ROOM, POOL DECK AND SWIMMING
 POOL?
  
 22) FBC 1007.8.1SHEET A7-4, WINDERS.
 THIS COMMENT HAS NOT BEEN PROPERLY
 ADDRESSED.ADDITION OF THE DIMENSION
 FOR TREAD DEPTH AT 12" FROM THE NARROW
 EDGE IS NOTED BUT WINDERS SHALL ALSO
 HAVE A MINIMUM TREAD DEPTH OF 6 INCHES
 AT THE NARROW EDGE.ANNOTATE THE PLAN
 TO DEMONSTRATE COMPLIANCE.
  
 27) FBC 3502SHEET S-0.0 GENERAL NOTES.
 THIS COMMENT HAS NOT BEEN ADDRESSED.
 THE PLAN STILL CITES ACI 318-99
 (REQUIREMENTS FOR STRUCTURAL CONCRETE)
 UNDER THE HEADING 'CODES' AND AGAIN
 UNDER THE HEADING 'THRESHOLD BUILDING
 INSPECTION PLAN'.THE CODE REFERENCED
 VERSION IS ACI 318-02.AMEND THE NOTE.
  
 28) FBC* 105.13.1SHEET S-0.0 THRESHOLD
 BUILDING INSPECTION PLAN.THIS COMMENT
 HAS NOT BEEN PROPERLY ADDRESSED.THE
 INSPECTION PLAN STILL LISTS STRUCTURAL
 PLAN SHEET NUMBERS WHICH ARE NOT
 APPLICABLE TO THIS PROJECT.AMEND THE
 THRESHOLD INSPECTION PLAN.
  
 34) THRESHOLD BUILDING INSPECTOR
 MEETING.PLEASE ARRANGE WITH HAROLD
 PISKURA (INSPECTION SERVICES MANAGER -
 TEL: 561 805 6711), A MEETING INVOLVING
 THE OWNER, THRESHOLD INSPECTOR, JOB
 INSPECTOR, CONTRACTOR AND ENGINEER.
  
 35) FBC 1805.1PILE FOUNDATIONS.THREE
 COPIES OF THE PILE DESIGN REPORT SHALL
 BE SUBMITTED FOR REVIEW.
  
 36) FOR FUTURE RESUBMITTALS/REVISIONS
 PLEASE CLOUD AND NUMBER THE REVISIONS.
  
 37) TO FACILITATE HANDLING AND REVIEW OF
 THE PLANS PLEASE DIVIDE THE
 ARCHITECTURAL, STRUCTURAL, AND MEP PLANS
 INTO SEPARATE ROLLS.
  
 38) TO EXPEDITE REVIEW OF A RESUBMITTAL
 WHICH REQUIRES NEW PLANS IN ORDER TO
 ADDRESS THE ABOVE COMMENTS, THE OLD
 SHEETS SHALL BE REMOVED AND THE NEW
 SHEETS INSERTED.ONE COPY OF EACH OLD
 SHEET SHOULD BE STAPLED/CLIPPED TO THE
 REMAINING OLD SHEETS, TO FORM A SET OF
 'OLD/VOID SHEETS', FOR COMPARISON OF
 REVISIONS WHEN REVIEWING THE RESUBMITTED
 PLANS.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS