| Date |
Text |
| 2006-11-10 12:52:18 | BUILDING PLAN REVIEW | | | ******PROVISO******* | | | ROBERT BROWN(561) 805 6652 | | | E-MAIL: [email protected] | | | | | | REVISION SUBMITTED ON 9/24/06 FOR WINDOW SHOP | | | DRAWINGS. | | | | | | --RESTRICTION-- | | | THE E.S. WINDOWS SERIES 4000 ALUMINUM SLIDING GLASS | | | DOOR SHALL NOT BE USED FOR SLIDING GLASS WINDOW TYPES | | | W5.1 OR W6.1.THOSE WINDOW TYPES EXCEED THE MAXIMUM | | | HEIGHT AND DESIGN POSITIVE PRESSURE STATED IN THE | | | SUBMITTED PRODUCT APPROVALNOA# 04-1117.05. | | | | | | --RESTRICTION-- | | | THE SMALL MISSILE IMPACT SMITH MOUNTAIN IMPACT SYSTEMS | | | SERIES SMI-175 ALUMINUM WINDOW WALL SYSTEM-S.M.I SYSTEM | | | SHALL NOT BE USED FOR POOL AREA STOREFROMT ST-05 OR | | | SIDELIGHTS TO STOREFRONT ST-04.THE GLASS PANEL SIZES | | | IN THOSE STOREFRONTS EXCEED THE MAXIMUM SIZES STATED IN | | | THE SUBMITTED PRODUCT APPROVALNOA# 05-0209.01. | | | | | | --ADDITIONAL CALCULATION REQUIRED-- | | | SUBMIT CALCULATIONS FOR THE HORIZONTAL MULLION REQUIRED | | | FOR STOREFRONT SF-4 |
|