2004-11-22 00:00:00******* UNSAT ********
  
 1)NOTE: PLEASE SEE PLANS REFERENCE PALM
 BEACH COUNTY. PLEAS SEE JOBSITE IS IN
 THE CITY OF WEST PALM BEACH.
  
 2)NOTE: PLEASE SEE 210.52D,210.11C3 FOR
 MIN REQUIRED BATH GFI. MUST BE 20A AND
 312 AWG.
  
 3)NOTE: PLEASE SEE 424.3B FOR SIZING OF
 OCP FOR AHU HEAT.
  
 4)NOTE: PLEASE SEE FBC CHAPTER 34 FOR
 ADDITIONS TO EXISTING DWELLINGS.
 PLEASE PROVIDE LAYOUT OF EXISTING SD'
 AND GFI EITHER EXISTING OR NEW TO MEET
 2002 NEC, NFPA-72 8-1.4.1.6.2
 *** THIS IS ONLY A NOTE***
 PLANS SHOW THREE SD'S IN MASTER BEDRM??
 PLEASE ALSO SEE SD'S IN LOCATIONS NOT
 REQUIRED. ?
 THIS IS NOT A CODE VIOLATION, ONLY NOTED
 FOR AMOUNT ABOVE REQUIRED?
  
 5)NOTE: PLEASE SEE FBC 104.2.1.
 PLEASE HAVE PERSON RESPONSIBLE FOR
 PLANS, SIGN WITH OUT RUBBER STAMP.
  
 6)NOTE: PLEASE SEE A/C DISCONNECT IS
 NOTED AS BEING 50A WHEN REQUIRED TO BE
 60A MIN.?
 424.3.B
  
 PLEASE SEE POSSIBLE COMMENTS FROM OTHER
 REVIEWERS WHICH MAY AFFECT ELECTRICAL
 PLANS.?
  
 PLEASE REMOVE ALL OLD VOIDED SHEETS AND
 ONLY INSERT NEW REVISED SHEETS INTO
 COMPLETE SETS FOR REVIEW AND STAMPING.
 ONE SET OF OLD SHOULD BE SUBMITTED FOR
 REFERENCE ONLY.
  
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  