| 2005-02-14 00:00:00 | DENIED |
| | REFERENCE: FBC-2001 PLUMBING |
| | FBC-2001 CHAPTER 11 |
| | |
| | A) FROM PREVIOUS REVIEW: |
| | 1) SHT A-2 KITCHEN SINK SHALL COMPLY |
| | WITH SECTION 4.24 AND ALL SUBSECTIONS. |
| | PLEASE SUBMIT A DETAIL. NO SUBMITTAL HAS |
| | BEEN SUBMITTED. |
| | 2) SHT A-2 DRINKING FOUNTAIN SHALL |
| | COMPLY WITH SECTION 11-4.15 AND ALL |
| | SUBSECTIONS. SUBMIT A DETAIL. ALSO SHOW |
| | COMPLIANCE WITH SECTION 11-4.1.3(10)(A) |
| | PROVISIONS FOR THOSE WHO HAVE DIFFICULTY |
| | BENDING OR STOOPING. NO SUBMITTAL HAS |
| | BEEN SUBMITTED. |
| | 3) TABLE 403.1 AUTOMATIC CLOTHES WASHER |
| | CONNECTIONS ARE REQUIRED. SHOW ON THE |
| | FLOOR PLAN, SANT. RISER DIAGRAM AND THE |
| | WATER RISER DIAGRAM. NOT ADDRESSED. |
| | 4) SUBMIT A WATER RISER DIAGRAM REQUIRED |
| | BY SECTION 104.3.1.1. SHOW ALL PIPE |
| | SIZES, VALVES AND WATER HAMMER ARRESTORS |
| | PER SECTION 606 & 604.9. NOT ADDRESSED. |
| | 6) THERMAL EXPANSION CONTROL IS REQUIRED |
| | AT ALL WATER HEATERS PER SECTION |
| | 607.3.2. SUBMIT A HEATER DETAIL SHOWING |
| | COMPLIANCE. |
| | 8) PLEASE NOTE THAT MOST OF THESE |
| | COMMENTS WERE STATED IN THE REVIEW OF |
| | PERMIT NUMBER 03011199. |
| | *************NEW COMMENTS********* |
| | 1B) FOR ACCESSIBLE TOILET ROOM SHOW THE |
| | FOLLOWING INFORMATION: |
| | A) CLEAR FLOOR SPACE 11-4.16.2 |
| | B) GRAB BARS PER FIG 29. 11-4.16.4 |
| | C) FLUSH CONTROLS 11-4.16.5 |
| | D) HEIGHT & CLEARANCES 11-4.19.2 |
| | E) CLEAR FLOOR SPACE 11-4.19.3 |
| | F) EXPOSED PIPES & SURFACES 11-4.19.4 |
| | G) TOILETS SHALL BE 18" FROM THE |
| | CENTERLINE OF THE FIXTURE TO THE WALL. |
| | FIGURE 28. |
| | H) LAV SHALL BE MINIMUM 15" FROM THE |
| | CENTERLINE OF THE FIXTURE TO THE WALL. |
| | SHALL BE CENTERED ON THE 30" OF THE |
| | CLEAR FLOOR SPACE. |
| | 2B) SHT A-3 SANITARY RISER DIAGRAM, THE |
| | TUBS IN ALL UNITS ARE NOT VENTED AS |
| | SHOWN. SECTION 901.2.1. |
| | 3B) DRAWINGS SHALL BE SPECIFIC, AND THE |
| | TECHNICAL CODES SHALL NOT BE CITED AS A |
| | WHOLE OR IN PART, NOR SHALL THE TERM |
| | "LEGAL" OR ITS EQUIVALENT BE USED AS A |
| | SUBSTITUTE FOR SPECIFIC INFORMATION. |
| | SECTION 104.2.1. |
| | 4B) SEE SHEET ATTACHED TO BUILDING PLAN |
| | REVIEWER'S NOTES CONCERNING DESIGN |
| | PROFESSIONAL & FS 553.80(2)(B). |
| | |