| 2004-12-09 00:00:00 | BUILDING PLAN REVIEW |
| | *******DENIED******* |
| | ROBERT BROWN(561) 805 6716 |
| | E-MAIL: [email protected] |
| | |
| | FBC = FLORIDA BUILDING CODE 2001 |
| | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) |
| | F.S.= FLORIDA (STATE) STATUTE |
| | |
| | 1) 713.13 F.S.A NOTICE OF |
| | COMMENCEMENT SHALL BE RECORDED AT PALM |
| | BEACH COUNTY COURTHOUSE AND A COPY |
| | SUBMITTED TO THIS OFFICE BEFORE A PERMIT |
| | CAN BE ISSUED. BLANK FORMS ARE AVAILABLE |
| | FROM THIS OFFICE. |
| | NOTE: THE NOTICE OF COMMENCEMENT MUST |
| | BE RE-RECORDED IF THE DESCRIBED |
| | IMPROVEMENT OR CONSTRUCTION IS NOT |
| | COMMENCED WITHIN 90 DAYS OF RECORDING. |
| | |
| | 2) 481.219 F.S.CERTIFICATE OF |
| | AUTHORIZATION.THE TITLE BLOCK FOR ANY |
| | SHEET BEARING THE NAME OF AN ARCHITECT |
| | PRACTICING UNDER A FICTITIOUS NAME, A |
| | CORPORATION, OR A PARTNERSHIP, OFFERING |
| | ARCHITECTURAL SERVICES, SHALL INCLUDE |
| | THE CERTIFICATE OF AUTHORIZATION |
| | NUMBER.ADD THE NUMBER TO EACH SHEET. |
| | THIS MAY BE ADDED BY HAND. |
| | |
| | 3) FBC 1004ARRANGEMENT AND NUMBER OF |
| | EXITS, SHEET A1.1.THE KEY NOTES STATE |
| | THAT THE DOOR FROM THE WAITING ROOM IS |
| | TO BE "..LOCKED/SECURED".ANNOTATE THE |
| | PLAN OR SUBMIT A SEPARATE LIFE SAFETY |
| | PLAN TO CLARIFY THE EXITING.IS |
| | BREAKROOM DOOR "EX2" A FIRE EXIT |
| | LEADING |
| | TO THE 'STREET'?PLEASE CLARIFY. |
| | |
| | 4) FBC 11-4.24.3BREAKROOM SINK. |
| | AMEND |
| | DETAIL J6 (SHEET A3.1) AND/OR THE FLOOR |
| | PLAN (SHEET A1.1) TO SHOW MIN. 30" WIDE |
| | X 19" DEEP KNEE CLEARANCE UNDER THE |
| | SINK.IT IS NOTED THAT THE REQUIRED |
| | MIN. 27" HEIGHT HAS ALREADY BEEN SHOWN |
| | ON SHEET A3.1 BUT DETAIL A11 (SHEET |
| | A4.1) DOES NOT CONCUR AND SHOULD BE |
| | STRUCK OUT IF NOT APPLICABLE.PLEASE |
| | CLARIFY.ALSO, ANNOTATE THE PLANS TO |
| | SHOW A MAX. SINK BOWL DEPTH OF 6.5" AND |
| | ANNOTATE THE PLANS TO STATE THAT THE |
| | SINK IS "ACCESSIBLE". |
| | |
| | 5) FBC 2405.2SHEET A3.1, DOOR |
| | SCHEDULE |
| | DOORS 3 AND 4 TYPE C AND D RESPECTIVELY |
| | (BOTH GLAZED DOORS) BUT THE SCHEDULE |
| | CALLS UP 'MATERIAL' AND 'FINISH' NOTE |
| | #1.SHOULD THIS NOT BE NOTE #3 WHICH |
| | CALLS FOR TEMPERED GLASS AND STATES THE |
| | REQUIRED 3/4-HOUR FIRE-RATING REQUIRED |
| | FOR DOOR 4?NOTE DOOR 3 DOES NOT |
| | REQUIRE FIRE-RATING.AMEND THE |
| | SCHEDULE |
| | |
| | **QUOTE PERMIT# ON ALL CORRESPONDENCE** |
| | |
| | END OF REVIEW COMMENTS |