| 2004-12-13 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 04110185 |
| | ADD: 3900 N FLAGLER DR (BLDG 3&6) |
| | CONT: MANHATTAN CONSTRUCTION |
| | TEL: (813)927-0209 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL |
| | LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT |
| | NUM- |
| | BER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR |
| | SPECIFICA |
| | TION PAGE WHERE THE CHANGES CAN BE |
| | FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. |
| | THANK |
| | YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | 1) THIS PERMIT IS FOR (2) |
| | BUILDINGS,(3&6) PROVIDE (2) PERMIT |
| | APPLICATIONS, FOR (2) SEPERATE PERMIT |
| | THIS WILL BE REQUIRED FOR THE REQUIRED |
| | INSPECTION SCHEDULING & TRACKING. |
| | 1A) PLANS NEED TO AGREE WITH THE PERMIT |
| | APPLICATION. EITHER THE APPLICATION |
| | SHOULD BE FOR ONE BUILDING, WITH A |
| | FULL NFPA 13 SPRINKLER SYSTEM NOT A 13R |
| | AS STATED IN THE FIRE SPRINKLER PLANS |
| | OR THERE NEEDS TO BE A 4 HR FIRE WALL |
| | SEPERATING THIS STRUCTURE INTO (2) |
| | STRUCTUCES, THE SECOND ISSUE WOULD BE |
| | TABLE 500, IF A FULL NFPA 13 SUPRESSION |
| | SYSTEM IS NOT USED YOU CAN NOT TAKE THE |
| | |
| | ALLOWABLE HEIGHT INCREASES ALLOWABLE IN |
| | TABLE 500 (FOOTNOTE "J"/SEE 903.2. |
| | UNTIL THIS ISSUE IS RESOLVED IT WILL BE |
| | DIFFICULT TO DETERMINE TABLE 500 |
| | ISSUES. |
| | |
| | 2) PROVIDE SQ. FT. AREAAS OF AREA FOR |
| | EACH FLOOR INCLUDE A/C SPACE AND NON- |
| | A/C SPACE. |
| | |
| | 3)AT PARKING SPACES COMPLYING WITH |
| | 11-4.1.2(5)(B), PROVIDE MINIMUM VERTICAL |
| | CLEARENCE OF 98" AT PARKING SPACES AND |
| | ALONG AT LEAST ONE VEHICLE ACCESS ROUTE |
| | TO SUCH SPACES FROM SITE ENTRANCES AND |
| | EXITS. |
| | PROVIDE THE MINIMUM CLEARENCE OF 114" |
| | AT ACCESSIBLE PASSENGER LOADING ZONES & |
| | AT LEAST 1 VEHICLE ACCESS ROUTE TO SUCH |
| | AREAS FROM SITE ENTRANCES & EXITS. |
| | |
| | 3) NOTE, NOT DISCUSSED UNDER BLDG# 1, |
| | IS |
| | SITE AMENITIES, GAURD HOUSE, WALLS, |
| | WALKWAYS, ETC... REQUIRE A SEPERATE |
| | PERMIT. ASSUMED SEAWALL IS ALREADY |
| | BUILT, IF NOT A SEPERATE PERMIT IS ALSO |
| | REQUIRED, SEE CITY CODE FOR REQUIRED |
| | SEAWALL APPROVALS. |
| | |
| | 4) COMMENTS FROM BLDG# 1 1-33 ALSO |
| | PERTAIN TO THIS REVIEW. |
| | |
| | 5)BEFORE A PERMIT TO CONSTRUCT, MAY BE |
| | ISSUED, IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY. THE ACTUAL PERMIT |
| | SET OF PLANS MUST BE STAMPED BY THAT |
| | OFFICE, AND A COPY OF THE PAID RECEIPT |
| | ATTACHED TO THE PERMIT APPLICATION. |
| | PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | |