| 2004-11-29 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 04100894 |
| | ADD: 2600 NORTH MILITARY TRAIL |
| | CONT: THE WEITZ CO |
| | TEL: (561)723-5976 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 1ST REVIEW |
| | 2ND SESSION STARTING COMMENT# 26 |
| | ACTION: FAILED |
| | |
| | |
| | 26) 1606.1.4(1) IN WIND BORNE DEBRIS |
| | REGIONS, EXTERIOR GLAZING THAT RECEIVES |
| | POSITIVE PRESSURE IN BUILDINGS SHALL BE |
| | ASSUMED TO BE OPENINGS UNLESS SUCH |
| | GLAZING IS IMPACT RESISTANT OR |
| | PROTECTED |
| | WITH AN IMPACT RESISTANT COVERING MEET- |
| | ING THE REQUIREMENTS OF SSTD 12, ASTM |
| | E 1886 AND ASTM E 1996 OR MIAMI-DADE. |
| | 1) GLAZED OPENINGS LOCATED WITHIN 30 |
| | FT |
| | OF GRADE SHALL MEET THE REQUIREMENTS OF |
| | LARGE MISSLE TEST. |
| | PRODUCT APPROVALS SUBMITTED WITH |
| | PERMIT APPLICATION AFTER OCTOBER 1, |
| | 2003 |
| | ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| | PRODUCT APPROVAL SYSTEM. FOR |
| | INFORMATION |
| | PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| | STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A COVER SHEET THAT LISTS |
| | THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. IF THE PRODUCT DOES NOT HAVE |
| | STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| | TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| | SPECIFIC FORM PER RULE 9B-72. SEE |
| | ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| | |
| | |
| | 27) FL BLD CODE 1606.1.5: COMPONENTS & |
| | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- |
| | OLD OR RESIDENT INSPECTOR) OF PRODUCT |
| | TESTING REPORTS,MISSING REPORTS ARE AS |
| | FOLLOWS: |
| | A) WINDOWS FIXED & OPARATABLE |
| | B) WINDOWS GLASS BLOCK |
| | C) MULLIONS |
| | D) DOORS, EXTERIOR W/ GLAZING |
| | E) DOORS, EXTERIOR SOLID |
| | F) LOUVERS |
| | G) COMPONENTS & CLADDING |
| | (1) CEMENT BOARD- SUBSHEATHING |
| | H) ROOFING ASSEMBLIES |
| | (1) INSULATION |
| | (2) ROOFING PRODUCTS |
| | |
| | 28)1707.4.3 EACH EXTERIOR DOOR |
| | ASSEMBLY NOT COVERED BY 1707.4.2 |
| | (GLAZED DOORS) SHALL BE LISTED AND |
| | TEST- |
| | ED FOR A PERIOD EQUAL TO THE QUANITY |
| | 3600/ V WHERE THE TIME PERIOD IS IN |
| | SECTIONS AND V IS IN MILES PER HR TAKEN |
| | FROM FIGURE 1606. THE TIME PERIOD SHALL |
| | ALSO INCLUDE A 10 SECOND PERIOD AT A |
| | LOAD EQUAL TO 1.5 TIMES THE DESIGN |
| | PRESSURE. DADE COUNTY & SBCCI REPORTS |
| | ARE ACCEPTED. |
| | |
| | 29) 1707.4.5.1 MULLIONS OCCURRING |
| | BETWEEN INDIVIDUAL WINDOW AND GLASS |
| | DOOR ASSEMBLIES. TESTING REPORTS ARE |
| | REQUIRED BY AN APPROVED TESTING |
| | LABORATORY OR BE ENGINEERED. |
| | |
| | 30) 1707.4.5.2 MULLIONS SHALL BE |
| | DESIGN- |
| | ED TO TRANSFER THE DESIGN PRESSURE |
| | LOADS |
| | APPLIED BY THE WINDOW OR DOOR |
| | ASSEMBLIES |
| | TO THE ROUGH OPENING SUBTRATE. |
| | |
| | 31) TABLE 803.3 MINIMUM INTERIOR FINISH |
| | CLASSIFICATION; PROVIDE INFORMATION |
| | BASED ON INTERIOR FINISH REQUIREMENTS |
| | BASED ON OCCUPANCY. |
| | |
| | 32) PROVIDE FLAMESPREAD AND SMOKE |
| | DEVELOPMENT INFORMATION ON THE GYM |
| | DIVIDING CURTAIN, TABLE 803.3. |
| | |
| | 33) PLEASE INDICATE EXITING (LIFE SAFETY |
| | PLAN) INDICATING OCCUPANT LOADS FOR |
| | ROOMS AND EXITING REQUIREMENTS SEE |
| | TABLE 1003.1. & TABLE 1004 FOR EXITS AND |
| | MEANS OF EGRESS. |
| | |
| | 34) A7.3 MEZZANINE DETAIL INDICATES THE |
| | USE OF A STEEL LADDEER VS STAIRS SEE |
| | 1005.7.3 EGRESS STAIRWAYS FROM |
| | MEZAANINES SHALL CONFORM WITH THE |
| | REQUIREMENTS OF 1007 ALSO SEE EXCEPTION |
| | AND REQUIRED SMOKE DETECTION SYSTEM AND |
| | FIRE ALARM. |
| | |
| | 35) BEFORE A PERMIT TO CONSTRUCT, MAY BE |
| | ISSUED, IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY. THE ACTUAL PERMIT |
| | SET OF PLANS MUST BE STAMPED BY THAT |
| | OFFICE, AND A COPY OF THE PAID RECEIPT |
| | ATTACHED TO THE PERMIT APPLICATION. |
| | PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |