| Plan Review Notes For Permit 04100753 |
| Permit Number |
04100753 |
|
| Review Stop |
P |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2005-02-23 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | FROM PREVIOUS REVIEW: | | | 1) KITCHEN SINK IS NOT VENTED. SECTION | | | 901.2.1. - IF THIS IS AN AIR ADMITTENCE | | | VALVE, THEN SHOW IT AS SUCH ON THE RISER | | | DIAGRAM. | | | 2) WASH MACHINE REQUIRES A STANDPIPE, | | | AND THE CLEANOUT SHALL BE INSTALLED 4' | | | ABOVE THE FLOOR FOR ACCESS. SECTIONS | | | 1002.1 AND 708.10 | | | 3) ANY PORTION OF THE DRAINAGE SYSTEM | | | INSTALLED UNDERGROUND, SHALL NOT BE LESS | | | THAN 2" IN DIAMETER. SECTION 710.3 | | | | | | 2) SEE SHEET 3/10 FOR RED LINE | | | CORRECTIONS TO BE MADE TO THE SANT. | | | RISER DIAGRAM. | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] | | | |
|