| 2004-11-04 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 04100740 |
| | ADD: 343 MONROE DRIVE |
| | CONT: NICK RAICH BLDG |
| | TEL: (561)718-1224 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | 1STREVIEW |
| | ACTION: DENIED |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| | BER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| | TION PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| | YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | 1)PROVIDE NOC RECORDED WITH THE CLERK |
| | OF COURT BEFORE A PERMIT CAN BE ISSUED. |
| | |
| | 2) FIRE DISTRICT F102.1 THERE IS NO |
| | TYPE |
| | VI (WOOD) ALLOWED IN THE FIRE DISTRICT. |
| | PROVIDE ADDITIONAL INFO. WHAT TYPE OF |
| | MATERIALS ARE THE EXTERIOR WALLS? IF THE |
| | EXTERIOR WALLS ARE BLOCK OR CLAY TILE |
| | THE INFILL AROUND THE WINDOWS CAN NOT BE |
| | |
| | WOOD FRAMED. |
| | |
| | 3) SHEET 2 OF 3 HEADER DETAIL INDICATES |
| | THE USE OF 2X6 HEADERS, SEE FBC TABLE |
| | 2308.3A FOR HEADED SPANS, 24' WIDE |
| | BUILD |
| | ING FOR A 8'-0" WINDOW WILL REQUIRE |
| | (2)- 2X12, SEE FOOTNOTES, 2&4. |
| | |
| | 4) FL BLD CODE 1606.1.5: COMPONENTS & |
| | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- |
| | OLD OR RESIDENT INSPECTOR) OF PRODUCT |
| | TESTING REPORTS,MISSING REPORTS ARE AS |
| | FOLLOWS: |
| | A) WINDOWS |
| | B) DOORS |
| | C) STORM SHUTTERS |
| | D) TRUSS ANCHORS |
| | E) ROOFING ASSEMBLIES |
| | |
| | 5) PRODUCT APPROVALS SUBMITTED WITH |
| | PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| | ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| | PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| | PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| | STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A COVER SHEET THAT LISTS |
| | THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. IF THE PRODUCT DOES NOT HAVE |
| | STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| | TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| | SPECIFIC FORM PER RULE 9B-72. SEE |
| | ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| | |
| | 6) SHEET 2 DETAILS INDICATE THE GARAGE |
| | DOOR TO BE INFILLED. ADDITIONAL INFO: |
| | A) PLYWOOD SUB-SHEATHING: |
| | 2304.5 CLEARENCE BETWEEN WOOD SIDING & |
| | EARTH ON THE EXTERIOR OF A BUILDING |
| | SHALL NOT BE LESS THAN 6" EXCEPT WHERE |
| | SIDING, SHEATHING AND FRAME WALL ARE OF |
| | APPROVED DURABLE WOOD OR APPROVED PRE- |
| | SERVATIVE TREATED WOOD. |
| | B)1403.1.6 IN OEDER TO PROVIDE FOR |
| | INSPECTION FOR TERMITE INFESTATION, |
| | CLEARENCE BETWEEN EXTERIOR WALL COVER- |
| | INGS AND FINAL EARTH GRADE ON THE |
| | EXTERIOR OF A BUILDING SHALL NOT BE LESS |
| | THAN 6 INCHES. |
| | |
| | 7) PLANS DO NOT INDICATE THE MATERIAL OF |
| | THE EXISTING RETAIL AREA. CHANGE OF |
| | OCCUPANCY REQUIRES THE FLOOR TO BE |
| | RECERTIFIED, FOR BUSINESS 50 PSF, AND |
| | FOR RETAIL 75 PSF (LIVE LOAD).TABLE |
| | 1604.1. |
| | |
| | 8)TOPLANDING OF HANDICAPPED RAMP TO HAVE |
| | A 5'-0" LANDING IN THE DIRECTION OF TRAV |
| | EL.11-4.8.4.(2) LANDINGS. ALL LANDINGS |
| | ON RAMPS SHALL NOT BE LESS THAN 60" |
| | CLEAR, & THE BOTTOM OF EACH RAMP SHALL |
| | HAVE NOT LESS THAN 72" OF STRAIGHT & |
| | LEVEL CLEARENCE. |
| | |
| | 9) 11.4.8.5. HANDRAILS: IF A RAMP HAS A |
| | RISE GREATER THAN 6" OR A HORIZONTAL |
| | PROJECTION GREATER THAN 72", THEN IT |
| | SHALL HAVE HANDRAILS ON BOTH SIDES. |
| | |
| | 10) DOORWAY LEADING TO THE HANDICAPPED |
| | RESTROOM TO COMPLY WITH : |
| | 11-4.13.5 DOORWAYS, MINIMUM |
| | CLEAR WIDTH: DOORWAY SHALL HAVE A MINI- |
| | MUM CLEAR OPENING OF 32" WITH THE DOOR |
| | OPEN 90 DEGREES, MEASURED BETWEEN THE |
| | FACE OF THE DOOR AND THE OPPOSITE STOP. |
| | THE CLEAR FLOOR SPACE BEFORE THE DOOR |
| | BEING 30" IS THE SAME DIMENSION AS THE |
| | DOORWAY. |
| | |
| | 11) CHANGE OF OCCUPANCY IMPACT FEES |
| | DUE, |
| | BEFORE A PERMIT TO CONSTRUCT, MAY BE |
| | ISSUED, IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY. THE ACTUAL PERMIT |
| | SET OF PLANS MUST BE STAMPED BY THAT |
| | OFFICE, AND A COPY OF THE PAID RECEIPT |
| | ATTACHED TO THE PERMIT APPLICATION. |
| | PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | BUILDING PLAN REVIEW |
| | JIM WITMER |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |