Plan Review Notes
Plan Review Notes For Permit 04100733
Permit Number 04100733
Review Stop B
Sequence Number 1
Notes
Date Text
2004-11-21 00:00:00****CORRECTIONS****
 FIRST REVIEW
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)PROVIDE A COPY OF THE RECORDED
 UNITY OF TITLE, OR PROVIDE THE
 BOOK/PAGE.
  
 2.)TWO DIFFERENT ADDRESSES WERE
 PROVIDED FOR THIS COMBINED PARCEL.
 PLEASE PROVIDE THE ADDRESS OF THE
 EXISTING RESTAURANT.THE PROPERTY
 APPRAISER USUALLY ASSIGNS THE LOWEST
 PARCEL ID AND ADDRESS WHEN TWO LOTS ARE
 COMBINED.PLEASE ADVISE AS TO WHETHER
 THIS IS ACCEPTABLE.
  
 3.)THE PARCEL BOUNDARY LINES ARE NOT
 CLEAR ON THE SURVEY.PLEASE PROVIDE
 LOT
 BOUNDARIES AND DIMENSIONS TO PROPOSED
 IMPROVEMENTS.
  
 4.)DECLARE A BUILDING TYPE AND
 INDICATE WHETHER OR NOT THE EXISTING
 BUILDING IS SPRINKLED TO SHOW FBC TABLE
 500 COMPLIANCE.
  
 5.)IMPACT FEES MAY BE DUE (PALM BEACH
 COUNTY).THE PLANS MUST BE STAMPED AND
 THE RECEIPT ATTACHED TO THE
 APPLICATION.
 233-5025.
  
 6.)THIS PARCEL IS IN A FLOOD ZONE,
 SEE
 SURVEY (A8).PROVIDE MINIMUM FLOOR
 ELEVATION, CITY OF WEST PALM BEACH
 MUNICIPAL CODE SEC.94-546(B)(2) (MIN.
 6"
 ABOVE BFE).
  
 7.)PROVIDE A SOILS INVESTIGATION
 REPORT, FBC1804.2.2.
  
 8.)PROVIDE ALL STRUCTURAL INFORMATION
 FOR THE AWNING.THIS CANNOT BE
 SUBMITTED AS SHOP DRAWINGS, REQUIRES
 PLAN REVIEW FOR CODE COMPLIANCE.
 PROVIDE DETAILS AND DESIGN LOAD
 INFORMATION, INCLUDING WIND DESIGN LOAD
 INFORMATION REQUIRED BY FBC1606.1.7.
 THERE IS A NOTE STATING THAT THE AWNING
 IS FLAME RETARDANT BUT NO OTHER
 INFORMATION IN REGARDS TO MATERIALS IS
 GIVEN FOR THE AWNING STRUCTURE.SHOW
 HOW IT WILL BE SUPPORTED STRUCTURALLY ON
 THE BUILDING SIDE, PROVIDE DETAIL OF
 ATTACHMENT.
  
 9.)A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED.
  
 10.) SEPARATE PERMITS FOR TRADES
 REQUIRED.
  
 11.)STATE OR LOCAL PRODUCT APPROVALS
 AND TEST REPORTS REQUIRED FOR THE
 WINDOW, DOOR, SHUTTERS, STRUCTURAL
 CONNECTORS, SEE FAC9B-72,
 WWW.FLORIDABUILDING.ORG.
  
 12.) ADDITIONAL FEES DUE (RADON),
 $9.00.
  
 13.)WHERE WILL THE HURRICANE SHUTTERS
 SHOWN ON THE PLAN BE STORED?
  
 14.)PROVIDE DIMENSIONS ON THE PLAN FOR
 THE AWNING.EDGE OF AWNING IS SHOWN,
 BUT NOT CONSISTENT WITH ELEVATIONS.
  
 15.)SHOW GRADE ON THE WALL SECTION
 A2.1.BOTTOM OF FOOTER IS TO BE NO LESS
 THAN 12" BELOW GRADE, FBC1804.1.3.
  
 16.)PROVIDE EMBEDMENT LENGTH OF STEEL
 INTO EXISTING, A2.1.
  
 17.)PROVIDE COUNTER HEIGHT; SHOW
 COMPLIANCE WITH FBC11-5.2.
  
 18.)IS THE SEATING FIXED?FBC11-5.1.
  
 19.)PROVIDE A FOUNDATION PLAN,
 FBC104.3.1.1(8).
  
  
  
  
  