| 2005-06-15 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 04100446 |
| | ADD: NOT YET ASSIGNED |
| | PCN: 74-43-43-09-11-003-0000 |
| | CONT: COMPLETE PROPERTY MANAGEMENT |
| | TEL: (561)252-8372 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | 2ND REVIEW |
| | ACTION: DENIED |
| | |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| | BER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| | TION PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| | YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | 1) FL BLD CODE 104.2.1.2 |
| | ADDITIONAL INFORMATION REQUIRED, |
| | INDICATE COMPLIANCE WITH 1804.2.2 |
| | QUESTIONABLE SOILS, ALLTERRA REPORT |
| | DATED MARCH 5/ 2004 INDICATES THAT PEAT |
| | WAS DISCOVERED WITH BORING# 2, SHOW HOW |
| | YOU WILL COMPLY WITH THIS SECTION? |
| | BORING # 2 & 3 BOTH INDICATE THE |
| | EXISTANCE OF PEAT BENEATH THE BUILDING. |
| | |
| | 2)COMMENT #3 FROM THE PREVIUOS REVIEW, |
| | FBC* 105.3RESIDENT INSPECTOR. |
| | SUBMIT INSPECTOR RESUME' AND LICENSE |
| | DOCUMENTS TO HAROLD PISKURA, DIRECTOR OF |
| | THE RESIDENT INSPECTOR PROGRAM.A |
| | RESIDENT INSPECTOR PROGRAM IS REQUIRED, |
| | ON THIS PROJECT, DUE TO ONE OR MORE OF |
| | THE FOLLOWING: |
| | - BUILDINGS/ADDITIONS OF TYPE I OR II |
| | CONSTRUCTION |
| | - ANY MAJOR STRUCTURAL ALTERATIONS |
| | - STRUCTURES IN WHICH THE CONCRETE |
| | DESIGN IS BASED ON COMPRESSIVE |
| | STRENGTH (F'C) IN EXCESS OF 3000 PSI |
| | - PILE DRIVING |
| | - BUILDINGS OVER 20,000 SQFT IN AREA |
| | - BUILDINGS OVER 2 STORIES IN HEIGHT |
| | - BUILDING/STRUCTURES OF UNUSUAL DESIGN |
| | OR METHODS OF CONSTRUCTION |
| | CALL HAROLD PISKURA FOR THE SPECIAL |
| | INSPECTOR PROGRAM AT 805-6711. |
| | |
| | 3) COMMENT# 6 FROM THE PEVIOUS REVIEW, |
| | BACK ENTRY DOORS INDICATE A 3/4 HR |
| | RATING, AS PER 705.1.1.2. THE SUBMITTED |
| | PRODUCT APPROVAL BENCHMARK EXTERIOR DOOR |
| | |
| | FL1190 IS TO BE USED FOR RESIDENTIAL |
| | USE, STEEL DOOR W/ WOOD JAMBS. PROVIDE |
| | THE FIRE TESTING REPORT OR PROVIDE |
| | ANOTHER PRODUCT. |
| | |
| | 4) COMMENT # 9 FROM THE PREVIOUS REVIEW, |
| | FL BLD CODE 1606.1.5: COMPONENTS & |
| | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- |
| | OLD OR RESIDENT INSPECTOR) OF PRODUCT |
| | TESTING REPORTS,MISSING REPORTS ARE AS |
| | FOLLOWS: |
| | A) TRUSS ANCHORS |
| | PRODUCT APPROVALS SUBMITTED WITH |
| | PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| | ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| | PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| | PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| | STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A COVER SHEET THAT LISTS |
| | THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. IF THE PRODUCT DOES NOT HAVE |
| | STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| | TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| | SPECIFIC FORM PER RULE 9B-72. SEE |
| | ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| | |
| | 4B) ROOFING: HIGHLIGHT WHICH TYPE OF |
| | ROOF TILE SHALL BE INSTALLED FROM THE |
| | TESTING REPORT. |
| | |
| | 4C) TAMCO ROOFING- MODIFIED,HIGHLIGHT |
| | WHICH DECK TYPE, DECK DESCRIPTION, & |
| | SYSTEM TYPE. SEE THE LIMITATIONS AND THE |
| | MAXIMUM DESIGN PRESSURE FOR EACH TYPE OF |
| | APPLICATION****** |
| | |
| | |
| | 5A) COMMENT # 10 FROM THE PREVIOUS |
| | REVIEW SHEET A-6 SOUTH ELEVATION |
| | INDICATES ARCHITECTURAL FEATURES ABOVE |
| | THE BEAMBUT NO INFORMATION, PLEASE |
| | PROVIDE? |
| | |
| | 5B) THE SAME SHEET A-6 SHOWS VARIOUS |
| | REVEALS ON BOTH THE FRONT AND REAR OF |
| | THE BUILDING, HOW IS THIS TO BE CREATED? |
| | |
| | 6) COMMENT# 11 FROM THE PREVIOUS REVIEW, |
| | BEFORE A PERMIT TO CONSTRUCT, MAY BE |
| | ISSUED, IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY. THE ACTUAL PERMIT |
| | SET OF PLANS MUST BE STAMPED BY THAT |
| | OFFICE, AND A COPY OF THE PAID RECEIPT |
| | ATTACHED TO THE PERMIT APPLICATION. |
| | PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | 7) S-6 BEAM SCHEDULE NOT LEGABLE, |
| | 104.2.1.3 THE BUILDING OFFICIAL MAY SET |
| | STANDARDS THROUGH DEPARTMENTAL POLICY |
| | STANDARDS FOR PLANS AND SPRCIFICATIONS. |
| | PLANS THAT ARE NOT LEGIBLE, STANDARDS |
| | ARE SET FOR CLARITY & CONTRAST. |
| | BUILDING PLAN REVIEW |
| | JIM WITMER |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |
| | |
| | |
| | |