Plan Review Notes
Plan Review Notes For Permit 04100446
Permit Number 04100446
Review Stop P
Sequence Number 1
Notes
Date Text
2004-11-01 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
  
 1) SHTS A-1 THRU A-4 A SERVICE SINK IS
 REQUIRED IN EACH SPACE PER TABLE 403.1
 2) SHT P-1 SANITARY RISER DIAGRAM DOES
 NOT MEET CODE REQUIREMENTS. NO FITTINGS
 APPROVED AS SHOWN ON RISER. SEE EXAMPLE
 OF TYPICAL BACK-TO-BACK AND SINGLE
 TOILET ROOM PIPING FOR RISER.
 2) AN RPZ BACKFLOW IS REQUIRED ON THE
 WATER SUPPLY TO THE BLDG. SECTION
 608.13.2
 3) INDICATE IF WATER RISER IS OVERHEAD
 OR UNDERGROUND. SECTION 104.2.1
  
  