| 2004-11-10 00:00:00 | CHECKLIST: |
| | 1-HOUSE IS LOCATED ON FLOOD ZONE A7. |
| | REVISE SURVEY AS REQUIRED. |
| | 2-NEED RECORDED NOTICE OF COMMENCEMENT. |
| | 3-BRING DWGS TO PALM BEACH COUNTY TO |
| | VERIFY IF IMPACT FEES ARE DUE OR IF |
| | CREDIT IS DUE. BRING BACK STAMPED DWGS |
| | AND COPY OF PAID RECEIPT. |
| | 4-SPECIFY JOINTS IN CONCRETE SLAB OR |
| | SPECIFY WWM SUPPORTS AND SPACING AS |
| | REQUIRED BY SEC. 1909.3 FBC 2001. |
| | 5-UPDATE ALL REFERENCE STANDARDS ON |
| | GENERAL NOTES. SEE CHAPTER 35 FBC 2001 |
| | FOR PROPER EDITION (YEAR) OF STANDARDS |
| | TO BE REFERENCED. |
| | 6-SPECIFY MASONRY OPENING FOR SINGLE |
| | HUNG WINDOWS 34E TO VERIFY COMPLIANCE |
| | WITH SEC. 1005.4.4 FBC 2001 FOR WINDOW |
| | CLEAR HEIGHT OPENING. |
| | 7-WHEN CREDIT FOR CEILING FANS IS TAKEN |
| | ON THE ENERGY CALCS, THEN, NEED TO |
| | SPECIFY SIZE OF FAN. SEE TABLE 6-6 ON |
| | CHAPTER 13 FBC 2001. |
| | 8-REVISE ENERGY CALCULATIONS. THERE IS |
| | NOT EXTERIOR FRAMED WALL BUT ADJACENT |
| | FRAMED WALL. |
| | 9-PROVIDE FLORIDA OR LOCAL PRODUCT |
| | APPROVAL FOR: A)SINGLE HUNG WINDOWS: |
| | FLORIDA PRODUCT APPROVAL NUMBER DOESN'T |
| | MATCH. |
| | B)GARAGE DOOR WITH SIZE OF DOOR AS SHOWN |
| | ON PLANS. ALSO, FLORIDA NUMBER DOESN'T |
| | MATCH. |
| | C)ENTRY DOOR AS SHOWN ON PLANS. |
| | D)EXTERIOR FRENCH DOORS WITH APPROVED |
| | FLORIDA BUILDING COMMISSION STATUTES. |
| | PENDING STATUS IS NOT ACEPTABLE. |
| | |
| | 10-PROVIDE COMPLETE INFORMATION FOR |
| | STORM SHUTTERS. NEED FLORIDA OR LOCAL |
| | PRODUCT APPROVAL ALONG WITH KEY PLAN AND |
| | COMPLETE INSTALLATION SCHEDULE. SEE |
| | ATTACHED SAMPLE. ALSO. INDICATE ON |
| | DRAWINGS SPECIFIC ANCHOR TYPE AND |
| | SPACING TO BE USED ACCORDING TO DESIGN |
| | PRESSURES, PANEL SPAN, EDGE DISTANCE, |
| | CONNECTOR TYPE AND STRUCTURE TO BE |
| | ATTACHED TO (MASONRY OR WOOD) |
| | 11-PROVIDE COMPLETE SPECIFICATIONS FOR |
| | ROOF ASSEMBLIES INCLUDING FASTENERS AS |
| | REQUIRED BY SEC. 104.2.1.1 OF CITY |
| | AMENDMENTS TO FBC 2001. |
| | 12-DECLARED VALUE WAS TOO LOW. IT WAS |
| | UPDATED TO $146,892. THEREFORE, |
| | ADDITIONAL FEES WILL BE ASSESSED. |
| | |
| | IF YOU HAVE ANY QUESTIONS, PLEASE CALL |
| | JULIO GOMEZ AT 805-6712. |