Plan Review Notes
Plan Review Notes For Permit 04100178
Permit Number 04100178
Review Stop P
Sequence Number 1
Notes
Date Text
2004-10-25 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
  
 1) SUBMIT A SANITARY RISER DIAGRAM SHOW-
 ING EXISTING RISER FOR LAV. SHOW HOW THE
 RISER FOR THE LAV IS BEING REROUTED. -
 SHOW HOW LAV WILL BE CONNECTED INTO THE
 EXISTING SANITARY. SECTIONS 104.2.1 AND
 104.3.1.1
 2) INDICATE DIMENSIONS OF POWDER ROOM.
 3) SHT MEP-2 PLUMBING NOTES:
 #5 AIR CHAMBERS ARE NOT APPROVED. DELE-
 TE FROM REFERENCE. SECTION 604.9
 #6 2-1/2" PIPE AND SMALLER SHAL SLOPE
 1/4" PER FOOT. TABLE 704.1 - CORRECT
 THE NOTE.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]