| 2004-11-30 00:00:00 | CHECKLIST: |
| | 1-PROVIDE ENERGY CALCULATIONS AS REQ'D |
| | BY SEC. 103 CHAPTER 13 FBC 2001. |
| | |
| | 2-PROVIDE SOIL TEST REPORT. |
| | |
| | 3-SPECIFY SIZE OF ATTIC ACCESS ABOVE |
| | MASTER BEDROOM WARDROBE. SEC. 2309.6 |
| | FBC |
| | |
| | 4-FLOOR PLANS ARE MISSING A LOT OF |
| | DIMENSIONS. ALSO, SOME DIMENSIONS ARE |
| | OVERLAPPING WITH OTHER INFORMATION AND |
| | ARE NOT LEGIBLE. |
| | **THERE ARE NOT DIMENSIONS FOR MASONRY |
| | OPENINGS AND FOR LOCATION OF CONCRETE |
| | BLOCK REINFORCING COLUMNS. SEC. |
| | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. |
| | |
| | 5-SPECIFY SAFETY GLASS WHERE REQUIRED |
| | BY |
| | SEC. 2405.2.1 FBC 2001. SEE PLANS. |
| | |
| | 6-REVISE STAIR WINDERS TO COMPLY WITH |
| | SECTION 1007.8.1 FBC 2001. |
| | |
| | 7-SPECIFY FIREBLOCKING AT STAIRS AS |
| | REQUIRED BY SEC. 2305.1.4 FBC 2001. |
| | |
| | 8-ONLY 2 SETS OF DRAWINGS ARE REQUIRED. |
| | |
| | 9-PROVIDE COMPLETE DETAILS/SPECS FOR |
| | CEILING INSTALLATION AT FRONT AND BACK |
| | PORCHES. SEC. 2504.2 FBC 2001 AND ASTM |
| | C926 AND ASTM C1063. |
| | |
| | 10-UPDATE TRUSS ANCHOR SCHEDULE. USE |
| | LATEST USP OR SIMPSON CATALOGUE. |
| | PROVIDE |
| | COMPLETE ENGINEERING CALCULATIONS FOR |
| | TYPE AND NUMBER OF FASTENERS THAT ARE |
| | DIFFERENT FROM THOSE PUBLISHED BY THE |
| | MANUFACTURER. SEC. 104.2.1.2 CITY |
| | AMENDMENTS TO FBC 2001. |
| | CLARIFY WHY ARE THERE ADDITIONAL |
| | FASTENERS SPECIFIED ON RIGHT HAND SIDE |
| | COLUMN OF TRUSS SCHEDULE. |
| | |
| | 11-PROVIDE COMPLETE FLORIDA OR LOCAL |
| | PRODUCT APPROVAL (2 COPIES) FOR: |
| | A) SINGLE HUNG WINDOWS. |
| | B) FIXED WINDOWS WITH SIZES AND SHAPES |
| | AS SHOWN ON PLANS. |
| | C) ROOF TILE. |
| | D) GLASS BLOCK. |
| | E) STRUCTURAL CONNECTORS (USP/SIMPSON). |
| | F) HORIZONTAL SLIDING WINDOWS. |
| | G) MECHANICAL ROOM EXTERIOR DOOR. |
| | H) FRENCH DOORS. |
| | I) ENTRY DOOR. |
| | |
| | 12-ENGINEER TO PROVIDE COMPLETE SPECS |
| | FOR ROOF ASSEMBLY, INCLUDING TILE |
| | FASTENING AS REQUIRED BY SEC. 104.2.1.1 |
| | CITY AMENDMENTS TO FBC 2001. |
| | |
| | 13-PROVIDE COMPLETE INFORMATION FOR |
| | STORM SHUTTERS INCLUDING: KEY PLAN AND |
| | COMPLETE INSTALLATION SCHEDULE (SEE |
| | SAMPLE). |
| | ALSO, CLEARLY MARK ON DRAWINGS SPECIFIC |
| | MOUNTING CONDITIONS AND ANCHOR TYPE AND |
| | SPACING TO BE USED ACCORDING TO THE |
| | DESIGN PRESSURES, EDGE DISTANCE, PANEL |
| | SPAN, CONNECTION TYPE AND STRUCTURE TO |
| | BE ATTACHED TO (MASONRY OR CONCRETE). |
| | |
| | 14-AFTER CORRECTIONS ARE DONE, PLEASE |
| | TAKE DRAWINGS TO THE HISTORIC DISTRICT |
| | FOR APPROVAL STAMPS PRIOR TO SUBMITTAL |
| | TO THE BUILDING DEPARTMENT TO EXPEDITE |
| | THE REVIEW PROCESS. |
| | |
| | 15-RE-SUBMITTAL FEES WILL BE CHARGED AT |
| | TIME OF RE-SUBMITTAL. SEE ENCLOSED FEE |
| | SCHEDULE. |
| | |
| | 16-DETAIL K ON SHEET A-11 IS MISSING |
| | INFORMATION. SEE PLANS. |
| | |
| | 17-PROVIDE ONLY DETAILS/SECTIONS THAT |
| | APPLY TO THIS PROJECT TO EXPEDITE REVIEW |
| | PROCESS AND AVOID CONFUSSIONS. |
| | |