| 2004-11-23 00:00:00 | CHECKLIST: |
| | 1-PAY IMPACT FEES. BRING BACK PAID |
| | RECEIPT AND STAMPED DRAWINGS. |
| | |
| | 2-NEED RECORDED NOTICE OF COMMENCEMENT. |
| | |
| | 3-ENTRY DOOR DOESN'T COMPLY WITH TABLE |
| | 1004 FBC 2001. NEED 32" MIN. CLEAR |
| | OPENING WHEN ONE LEAF IS OPEN. REVISE. |
| | |
| | 4-BEDROOM IN GUEST ROOM TO HAVE DOOR |
| | THAT PROVIDES 29" CLEAR OPENING. SECTION |
| | 11-11 OF FBC 2001 CHAPTER 11. |
| | |
| | 5-GUEST BEDROOM WINDOW DOESN'T COMPLY |
| | WITH SEC. 1005.4.4 FBC 2001. MULLION |
| | DOESN'T ALLOW THE 20" MIN. CLEAR |
| | OPENING. REVISE AS REQUIRED. |
| | **SAME COMMENT APPLY FOR DEN ROOM. (IF |
| | USING THE ROOM FOR SLEEPING. OTHERWISE, |
| | CLEARLY INDICATE UNDER THE DEN THAT ROOM |
| | CAN NOT BE USED FOR SLEEPING PURPOSES. |
| | |
| | 6-ELEVATIONS AND FLOOR PLANS DON'T |
| | MATCH. SEE NUMBER AND LOCATION OF |
| | FIREPLACES AND REVISE/CLARIFY AS REQ'D. |
| | |
| | 7-PROVIDE ATTIC ACCES AT FAMILY ROOM |
| | WING. SEC. 2309.6 |
| | |
| | 8-UPDATE CONNECTOR SCHEDULE. SEE CURRENT |
| | SIMPSON CATALOGUE AND REVISE TYPE AND |
| | NUMBER OF FASTENERS TO MATCH ENGINERED |
| | PUBLISHED VALUES. SEE COMMENTS ON PLAN. |
| | |
| | 9-PROVIDE ONLY DETAILS THAT APPLY TO |
| | THIS PROJECT TO EXPEDITE THE REVIEW. |
| | |
| | 10-SPECIFY ROOF TILE FASTENERS. SEE SEC. |
| | 104.2.1.1 CITY AMENDMENTS TO FBC 2001. |
| | |
| | 11-PROVIDE COMPLETE DRAWINGS AND SPECS |
| | FOR ELEVATOR OR APPLY FOR A SEPARATE |
| | PERMIT. INCLUDING ELEVATOR MACHINE |
| | ROOM. |
| | |
| | 12-PROVIDE FLORIDA/LOCAL PRODUCT |
| | APPROVAL FOR: A) TRUSS CONNECTORS USED. |
| | B) CASEMENT WINDOWS. |
| | C) WINDOW/DOOR MULLIONS: CLEARLY SPECIFY |
| | MULLION SIZE AND FASTENERS TO BE USED. |
| | D) ARCHED WINDOWS. |
| | E) FRENCH DOORS. |
| | F) GARAGE SIDE DOOR. |
| | G) COMPLETE PACKAGE FOR FIREPLACE LISTED |
| | TO BE USED OUTDOORS. |
| | H) BBQ UL LISTING AND SPECS. |
| | |
| | 13-OWES $3,709.54 FOR UPDATED VALUE AND |
| | BALANCE DUE AT TIME OF APPLICATION. |
| | |
| | 14-UPDATE REFERENCE STANDARDS SHOWN ON |
| | PAGE A-1. SEE COMMENTS AND CHAPTER 35 OF |
| | FBC 2001 FOR CURRENT EDITION TO BE |
| | USED. |
| | |
| | 15-SHEET A-5: "D" CONNECTOR DOESN'T |
| | RESIST THE UPLIFT CALCULATED ON PLAN. |
| | SEE COMMENTS ON PLAN & REVISE AS REQ'D. |
| | ** SAME APPLIES TO SHEET A-6. |
| | |