| Plan Review Notes For Permit 04090764 |
| Permit Number |
04090764 |
|
| Review Stop |
B |
| Sequence Number |
7 |
|
| Notes |
| Date |
Text |
| 2007-01-24 17:04:34 | DENIED BY BUILDING | | | | | | 1)ALL OF THE NEW REVISIONS TO THE PLANS ARE NOT | | | CLOUDED AND MARKED WITH THE REVISION NUMBER INSIDE THE | | | TRIANGLE. | | | | | | 2) THE TITLE BLOCKS ARE MISSING THE REVISION NUMBERS ON | | | SEVERAL SHEETS. | | | | | | 3) THE REVISION DATES IN THE TITLE BLOCK HAVE BEEN | | | PARTIALLY CUT OF ON SHEET A6. | | | | | | 4) SPECIFY THE SIZES OF THE ATTIC ACCESS OPENINGS. | | | | | | 5) THE ATTIC ACCESS FROM THE SECOND FLOOR TO AHU-3 DOES | | | NOT NEED TO BE SHOWN ON THE FIRST FLOOR PLAN A-2. SHOW | | | IT AS A DOOR IN THE WALL OF CLOSET 204 ON THE SECOND | | | FLOOR PLAN A-3. | | | | | | 6) WINDOWS (B) IN THE RECONFIGURED 2ND FLOOR SHOWER ARE | | | BOTH REQUIRED TO HAVE SAFETY GLAZING OR BE IMPACT | | | RESISTANT. THE WINDOW SCHEDULE SHOWS ONLY ONE WITH | | | TEMPERED GLASS. PRODUCT APPROVALS SUBMITTED ARE FOR | | | LARGE MISSLE IMPACT GLAZING. | | | | | | 7)PLEASE CORRECT THE DOOR AND WINDOW SCHEDULE ON A-9. | | | SECOND FLOOR DOORS 71 AND 72 HAVE BEEN OMITTED BUT ARE | | | STILL SHOWN ON A-3. CHECK DOORS 15, 16, 46 AND 63 ON | | | THE FIRST FLOOR. | | | | | | 8) REVISIONS TO OTHER TRADES AFFECTED BY THESE CHANGES | | | WILL BE REQUIRED. | | | | | | 9) THE DIMENSIONS LISTED IN ROOM 128 ARE ILLEGIBLE. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|