Plan Review Notes For Permit 04090764
Permit Number 04090764
Review Stop B
Sequence Number 2
Notes
Date Text
2005-01-10 00:00:00DENIED
  
 1)A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
  
  
 2) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 3) THE SAFETY GLAZING IN BATH #2 IS
 SPECIFIED FOR THE WRONG WINDOW. PLEASE
 CORRECT.
  
 4) SUBMIT AN AFFIDAVIT FROM THE ASPHALT
 BASED ROOFING PRODUCT MANUFACTURER
 CERTIFYING THE USE OF THEIR PRODUCT OVER
 AN UNVENTED ATTIC SYSTEM. SEE ATTACHMENT
 FROM PALM BEACH COUNTY BCAB.
  
 5) SPECIFY THE SCUPPER SIZES FOR
 DRAINING THE FLAT ROOFS.
  
 6) RISER AND TREAD DIMENSIONS DO NOT
 COMPLY WITH FBC 1007.3.1.
  
 7) SHOP DRAWING WILL BE REQUIRED FOR THE
 FLOOR SYSTEM AT THE SECOND FLOOR.
  
 8) ITEM NUMBER (14) FROM THE FIRST
 REVIEW STATES THAT BUCK FASTENING
 DETAILS ON A10 CONFLICT WITH THOSE ON
 S4. THE NOTES ON THE BUCK DETAILS ON A10
 REFER TO S4 FOR DETAILS. THERE WAS NO
 SHEET S4 SUBMITTED.
  
 9) SUBMIT STRUCTURAL DETAILS FOR
 FIREPLACE AND CHIMNEY CONSTRUCTION.
 SPECIFY THE REQUIRED HEIGHT OF THE
 CHIMNEY ABOVE THE ROOF AND ROOF
 STRUCTURES. FBC 2114.3.2 REQUIRES THE
 FIREBOX TO HAVE A MINIMUM DEPTH OF 20"
 AND A THROAT AT LEAST 8" ABOVE THE
 FIREPLACE OPENING. SEE FBC 2114.3.8 FOR
 HEARTH DIMENSIONS.
  
 10) PRODUCT APPROVALS SUBMITTED
 WITH PERMIT APPLICATION AFTER OCTOBER 1,
 2003 ARE REQUIRED TO COMPLY WITH THE
 FLORIDA PRODUCT APPROVAL SYSTEM. FOR
 INFORMATION PLEASE SEE THE STATE WEBSITE
 AT WWW.FLORIDABUILDING.ORG. PRODUCTS
 WITH STATEWIDE APPROVAL ARE REQUIRED TO
 BE SUBMITTED WITH A COVER SHEET THAT
 LISTS THE PRODUCT IDENTITY NUMBER FROM
 THE STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. PLEASE
 SUBMIT THE COVER SHEETS WITH THE FL
 NUMBERS FOR EACH PRODUCT FROM THE STATE
 WEBSITE.
  
 11) SUBMIT THE FLORIDA PRODUCT APPROVALS
 FOR ALL OF THE TRUSS CONNECTORS THAT ARE
 SPECIFIED ON THEPLANS.
  
 12) SUBMIT STATE OR LOCAL PRODUCT
 APPROVALS WITH INSTALLATION INSTRUCTIONS
 FOR THE FOLLOWING:
 - ACHED TOP CASEMENT WINDOWS
 - HOPPER WINDOWS
  
 13) THE PRODUCT APPROVAL THAT WAS
 SUBMITTED FOR THE SLIDING GLASS DOOR HAS
 ONLY SMALL MISSLE IMPACT RATING AND WILL
 BE REQUIRED TO BE COVERED BY STORM
 PANELS. SUBMIT STORM PANEL PRODUCT
 APPROVAL KEY PLAN AND INSTALLATION
 INSTRUCTIONS.
  
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714