Plan Review Notes
Plan Review Notes For Permit 04090575
Permit Number 04090575
Review Stop B
Sequence Number 3
Notes
Date Text
2005-01-19 00:00:00CHECKLIST:
  
 1-REVISE ENTRY PORCH ROOF FRAMING PLAN
 AND ALL DETAILS. CHECK BEARING HEIGHTS
 AND FRAMING OF ENTRY PORCH. CLEARLY
 SPECIFY ALL CONNECTORS INCLUDING AT TOP
 AND BOTTOM CONNECTIONS. SECTION
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
  
 2-CHIMNEY IS SHOWN ONLY ON THE FRONT
 ELEVATION. SHOW CHIMNEY ON ALL
 ELEVATIONS AS REQUIRED. SEC. 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.
  
 3-FIREPLACE: PROVIDE MANUFACTURER'S
 SPECIFICATIONS THAT ALLOWS FLUE CAP TO
 HAVE CEILING ABOVE. SPECIFY ALL
 REQUIRED
 CLEARANCES TO ALLOW PROPER EXHAUST OF
 FUMES. SEC. 104.2.1.2 CITY AMENDMENTS
 TO
 FBC 2001.
  
 4- PROVIDE SPECIFIC LISTING SHOWING
 COMPLIANCE WITH UL 127. SEE SECTIONS
 2806.1.1 AND 2806.1.2 FBC 2001.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 805-6712.