| Plan Review Notes For Permit 04090575 |
| Permit Number |
04090575 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2004-10-21 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1) SHT A4 0F 7 SANITARY RISER DIAGRAM | | | DOES NOT REFLECT THE FLOOR PLAN. | | | A) CABANA BATH SHOWS A SHOWER ON THE | | | RISER DIAGRAM THAT IS NOT ON THE FLOOR | | | PLAN. SECTION 104.2.1 | | | B) MASTER BATH SHOWS THE BIDET TO THE | | | RIGHT OF THE W/C ON THE FLOOR PLAN, NOT | | | BETWEEN THE W/C AND THE LAV AS SHOWN ON | | | THE RISER DIAGRAM. SECTION 104.2.1 | | | C) THE WASH MACHINE REQUIRES A STAND- | | | PIPE. SECTION 1002.1 & 802.4. - ALSO THE | | | WASH MACHINE CLEANOUT SHALL BE 4' ABOVE | | | THE FLOOR FOR ACCESS. SECTION 708.10. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|