Plan Review Notes
Plan Review Notes For Permit 04090541
Permit Number 04090541
Review Stop P
Sequence Number 2
Notes
Date Text
2005-01-31 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 11
  
 1) SHT P-1 FULL OPEN VALVES SHALL BE
 INSTALLED ON THE TOP OF EVERY WATER
 DOWN-FEED PIPE. SECTION 606.1(4).
 2) FROM PREVIOUS REVIEW: SUBMIT A DETAIL
 SHOWING COMPLIANCE WITH THE FOLLOWING:
 11-4.16.2 CLEAR FLOOR SPACE
 11-4.16.3 HEIGHT
 11-4.16.4 GRAB BARS
 11-4.16.5 FLUSH CONTROLS
 11-4.19.2 HEIGHT & CLEARANCES
 11-4.19.4 EXPOSED PIPES AND SURFACES
 11-4.19.5 FAUCETS
 WATER CLOSET SHALL BE 18" OFF THE WALL
 TO THE CENTERLINE OF THE FIXTURE. FIG.
 28
 LAV SHALL BE MINIMUM OF 15" OFF THE WALL
 TO THE CENTERLINE OF THE FIXTURE TO BE
 CENTERED ON THE 30" MEASURMENT OF THE
 CLEAR FLOOR SPACE.
  
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]