| 2005-01-25 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT:04090541 |
| | ADD: 747 N CONGRESS |
| | CONT: WCI |
| | TEL: (561)662-3569 |
| | BLD CODE= 2001 FLORIDA BUILDING CODE * |
| | WEST PALM BEACH AMENDMENTS |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | |
| | 1) COMMENT# 4 FROM THE PREVIOUS REVIEW |
| | SHEET S-2 WIRE LATH FASTENING SCHEDULE. |
| | 104.2.1 W.P.B. ADMINISTRATIVE CODE |
| | DRAWINGS & SPECIFICATIONS SHALL CONTAIN |
| | INFORMATION, IN THE FORM OF NOTES OR |
| | OTHERWISE, AS TO THE QUALITY OF |
| | MATERIALS, WHERE QUALITY IS ESSENTIAL TO |
| | CONFORMITY WITH THE TECHNICAL CODES. |
| | SUCH INFORMATION SHALL BE SPECIFIC |
| | AND THE TECHNICAL CODES "SHALL NOT BE |
| | CITED AS A WHOLE OR IN PART, NOR THE |
| | TERM "LEGAL" OR ITS RQUIVALENT BE USED |
| | AS A SUBSTITUTE FOR SPECIFIC |
| | INFORMATION". |
| | PROVIDE THE ACTUAL DIAMETER & LENGHT |
| | OF NAILSREQUIRED FOR FLAT WIRE LATH |
| | AND RIBBED LATH BOTH FOR HORIZONTAL AND |
| | VERTICAL SURFACES. WE ALSO NEED TO KNOW |
| | THE WEIGHT OF THE WIRE LATH SPECIFIED |
| | FOR HRIZONTAL RUNS FOR SPAN LIMITATION. |
| | THE CODE REFERS YOU TO ASTM C-1063 TO |
| | LOCATE THE REQUIRED SPANS WEIGHT AND |
| | NAIL PENETRATION REQUIRED FOR EACH |
| | APPLICATION. |
| | |
| | 2)BEFORE A PERMIT TO CONSTRUCT, MAY BE |
| | ISSUED, IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY. THE ACTUAL PERMIT |
| | SET OF PLANS MUST BE STAMPED BY THAT |
| | OFFICE, AND A COPY OF THE PAID RECEIPT |
| | ATTACHED TO THE PERMIT APPLICATION. |
| | PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | BUILDING PLAN REVIEW |
| | JIM WITMER |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |