| 2005-03-10 00:00:00 | PERMIT 04090391 | | | BLDG # 29 | | | 4700 PORTOFINO WAY | | | | | | 03-09-05 BUILDING PLANS ARE CODE | | | COMPLIANT/ REQUIRES IMPACT FEES/ & | | | REMAINDER OF PERMIT PAYMENT BEFORE | | | ISSUANCE. | | | | | | BUILDING PROVISO: | | | 1)TRUSS DRAWINGS TO BE REVIEWED BY THE | | | DESIGN PROFESSIONAL. | | | | | | 2)TRUSS DRAWINGS TO BE RESUBMITTED | | | BEFORE THE TRUSS ANCHOR AND TRUSS | | | FRAMING INSPECTION WITH CORRECTIONS. | | | .TRUSS ENGINEERING - IF THEY USE | | | "FBC2001/ANSI95" FOR THE CODE, ALONG | | | WITH THE PLATES INCREASE OF 1.33, IT | | | USES A STRESS INCREASE FOR STEEL WHICH | | | IS NOT PERMISSIBLE.THIS IS PER MITEK, | | | THE SOFTWARE COMPANY.THE CORRECT CODE | | | REFERENCE IS "FBC2001/TPI2002", WHICH | | | DOES NOT TAKE A STRESS INCREASE FOR | | | STEEL EVEN IF A 1.33 PLATE INCREASE IS | | | USED. | | | | | | 3) TRUSS SHOP DRAWING TO BE ORIGINAL | | | SIGNATURES AND SEAL OR HAVE A SIGNED & | | | SEALED INDEX PAGE LISTING ALL DRAWINGS. | | | SEE 61G15-23.002(2) | | | | | | | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|