2005-02-15 00:00:00BUILDING PLAN REVIEW
  
 PORTOFINO PHASE II
  
 PERMIT: 04090383
 ADD: MASTER BLDG TYPE I
 CONT:EPOCH PROPERTIES
 TEL: (561)723-0152
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 3RD REVIEW
 ACTION: DENIED
  
 1) COMMENT #4 FROM THE PREVIOUS REVIEW,
 SHEET A-DT4 DETAIL "J", PLANS HAVE A
 HIGH VALUE OF 1450 SEE 2005 CATALOG
 VALUE OF 1225.
  
 2) COMMENT #6 FROM THE PREVIOUS REVIEW,
 WITH THE HURRICANE PREPAREDNESS PLAN,
 REVISE:
 A) AMOUNT OF ON SITE STAFF
 B) NO RESIDENCE TO HELP
 C) PROVIDE LABOR FORCE CONTRACT
 D) START ISSUANCE OF PLAN AT THE
 HURRICANE WATCH NOT WARNING
 E) SHUTTERS TO BE DOWN AS SOON AFTER
 THE STORM AS RESONABLY POSSIBLE.
  
 3) COMMENT #7 FROM THE PREVIOUS REVIEW,
 DEALS WITH THE SOILS REPORTS:
 3A) ONLY 1 SIGNED & SEALED COPY OF THE
 REPORT WAS SUBMITTED, (3)SIGNED & SEALED
  
 REPORTS ARE REQUIRED , RESIDENT
 INPSECTOR PROGRAM.
 3B) THE ENGINEERING LETTER DATED
 12/15/04 FROM PSI ALSO IS REQUIRED TO BE
  
 SIGNED AND SEALED. AGAIN (3) ORIGINAL
 SIGNATURES SIGNED & SEALED.
 PLANS, SPECIFICATIONS,REPORTS OR
 OTHER DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS4)
  
 4) COMMENT #9 FROM THE PREVIOUS REVIW,
 FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORTS,MISSING REPORTS ARE AS
 FOLLOWS:
 A) STORM SHUTTERS
 PROVIDE STORM PANEL INFORMATION WITH
 INSTALLATION SCHEDULE AND KEY PLAN WITH
 SPECIFIC ANCHORS AND MOUNTING TO BE USED
 FOR ALL NON-IMPACT GLAZING.
 FBC 1606.1.4.
 FL BLD CODE 2001 SECTION 103.6,
 1606.1.4, 1707.4 & 3401.7.2.4.
 PROCEDURES: 1(B) A COMPLETE INSTALLATION
 SCHEDULE SUMMARIZING & IDENTIFYING
 OPENING SIZES, STORY HEIGHTS, UNIT MARK
 NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM
 BAR REINFORCING REQUIREMENTS, WALL PRES-
 SURE ZONES, SLAT TYPES, ETC., SHALL BE
 SUBMITTED AT TIME OF PERMIT APPLICATION
 TO FACILITATE PLAN REVIEW AND PERMIT
 ISSUANCE.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 5) COMMENT #10 FROM THE PREVIOUS REVIEW,
 DEEALS WITH THE MINIMUM DEPTH OF THE
 FOUNDATION, THE EXTERIOR GYPSUM BOARD
 IS TO STOP 8" FROM GRADE SEE (2506) AND
 THE FOUNDATION IS TO BE A MINIMUM OF 12"
 BELOW GRADE, YOUR GEO REPORT RECOMENDS
 16", THE 2 COMBINED EQUAL A DEPTH OF 24"
 TO THE TOP OF SLAB. S-D1.1 INDICATES
 THIS ON THE DETAILS BUT THE FOUNDATION
 SHEET WAS NEVER CHANGED TO MATCH THE NEW
 DETAILS, SEE FOUNDATION WF-16A & WF-24A
 ON SHEET S-D4.
  
 6) BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026