2004-10-25 00:00:00BUILDING PLAN REVIEW
  
 PORTOFINO PHASE II LAND, LTD
 BUILDING TYPE I
 PERMIT: 04090383BLDG# 22
 ADD: 4650 PORTOFINO WAY
 PERMIT: 04090384BLDG# 23
 ADD: 4635 PORTOFINO WAY
 CONT: EPOCH PROPERTIES, INC.
 TEL: (407)718-8932
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1STREVIEW
 ACTION: DENIED
  
 1) THE INCORRECT PROPERTY CONTROL NUMBER
 WAS USED AND CORRECT THE ADDRESSES FOR
 PHASE II DATED SEPT 21/04.
  
 2) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 3) SHEET A-U13 DETAILS INDICATE THE USE
 OF SEMCO STRAPS. SEMCO WAS BOUGHT OUT IN
 1999 BY USP, UPDATE PLANS TO REFLECT THE
 MANUFACTURER, MODEL NUMBER, ANDLOADS TO
 BEIMPOSED.SHEET A-T1.3 HURRICANE STRAP/
 CONNECTION NOTES ALSO REFRENCE SEMCO
 PRODUCTS. DELETE SEMCO FROM A-DT4.
  
 4) SHEET A-T1.3ROOF SHEATHING NOTES,
 23.22.2.5, DEALS WITH HIGH VELOCITY
 HURRICANE ZONES, 2306.1* ZONE# 3 EDGE
 NAILING ZONES BETWEEN 25'-35' REQUIRE
 8D RING SHANK NAILS @ 4" O.C. EDGES AND
 6"O.C. INTERMEDIATES.
 ENGINEER OF RECORD WILL PROVIDE ADDITION
 AL INFORMATION ON ROOF SHEATHING NAILING
 ABOVE 35'.
  
 5) SHEET A-T1.3 HURRICANE STRAPS:
 A) USP TSUA24/26 TUNNEL TIE NOT LISTED
 IN THE 2004 CATALOG.
 B) USP DTC LISTED IN USP CATOLOG AS
 ROOF TRUSS CLIPS
 C) USP RT 24VALUE ON PLANS IS HIGH
 SEE FOOTNOTE IN USP ( VALUES REPRESENT
 LOADS WHICH DO NOT INCLUDE A STEEL
 INCREASE ON THE STEEL CALCULATION).
 1609.4.3 LOAD REDUCTION.
 WHEN STRUCTURAL EFFECTS DUE TO TWO OR
 MORE LOADS IN COMBINATION WITH DEAD LOAD
 ARE INVESTIGATED IN LOAD COMBINATIONS OF
 1609.4.1 OR 1609.4.2, THE COMBINED
 EFFECTS DUE TO THE TWO OR LOADS MULTI-
 PLIED BY 0.75 PLUS EFFECTS DUE TO DEAD
 LOADS SHALL NOT BE LESS THAN THE EFFECTS
 FROM THE LOAD COMBINATION OF THE DEAD
 LOAD PLUS THE LOAD PRODUCING THE LARGEST
 EFFECTS. INCREAS IN ALLOWABLE STRESS SPE
 CIFIED IN THE MATERIALS SECTIONS OF THIS
 CODE OR A REFRENCED STANDARD SHALL NOT
 BE USED WITH THESE LOAD COMBINATIONS
 EXCEPT THAT A DURATION OF LOAD INCREASE
 SHALL BE PERMITTED IN ACCORDANCE WITH
 CHAPTER 23.
  
 6)903.8.2 FLOR ST STATUTE 553.895(2)
 ALL RESIDENTIAL BUILD. 3 OR MORE STORIES
 TALL WHETHER DESIGNATED AS TOWNHOUSE,
 CONDOMINIUMS, "APARTMENT HOUSES,
 TENEMENTS, GARDEN APARTMENTS OR BY ANY
 OTHER NAME SHALL BE SUPPLIED BY FIRE
 SPRINKLERS MEETING NFPA 101.
  
 7) A-DT1 WINDOW AND DOOR SCHEDULE, PLANS
 DO NOT INDICATE IF THIS SCHEDULE IS FOR
 (4)INTERIOR ZONES OR (5) END ZONES. ALSO
 THERE IS A MULTIPLIER OF 1.12 FOR OVER
 40' SEE 1606.2D.
  
 8) A-DT1 HARDWARE NOTES (6) IMPLIES THAT
 ON THE 2ND & 3RD FLOORS ONLY THE SLIDING
 GLASS DOORS REQUIRES IMPACT GLASS. THE
 CITY'S OFFICIAL INTERPERTATION LIST ON
 LAGRE PROJECTS THAT A PRE-STORM PREPARED
 NESS PLAN MUST BE SUBMITTED BY THE PROP
 ERTY OWNERS OR MANAGING AGENTS FOR
 REVIEW BY THE CONSTRUCTION SERVICES DEPT
 ANY SUCH PLAN SHALL INCLUDE, AT A MINI-
 MUM ON-SITE LOCATION OF SHUTTERS, PARTY
 RESPONSIBLE FOR SECURING THE SHUTTERS,
 (SAID PARTY MUST LIVE WITHIN PALM BEACH
 COUNTY) TOTAL NUMBER OF OPENINGS TO BE
 PROTECTED AND THE TOTLA TIME REQUIRED TO
 SECURE ALL OPENINGS. PROTECTION OF OPEN-
 INGS SHALL BE ACCOMPLISHED WITHIN (12)
 HOURS OR LESS OF THE OFFICIAL
 NOTIFICATION BY THE NATIONAL WEATHER
 SERVICE OF A HURRICANE WATCH.
  
 9) SHEET A-DT2 DETAILS 7&8 PROVIDE A
 CLEAR DETAIL OF THE STUCCO REVEL & THE
 EXSPANSION CONTROL JOINT, (ASTM 1063).
 INDICATE HOW THE WATER TIGHT MEMBRANE
 WILL OCCUR?
  
 10)FL BLD CODE 1804.2.2 QUESTIONABLE
 SOILS, WHERE THE BEARING CAPACITY IS
 NOT DEFINETLY KNOWN OR IS IN QUESTION.
 WHERE THE BEARING CAPACITY OF THE SOIL
 IS NOT DEFINITLY KNOWN OR IS IN QUESTION
 THE BUILDING OFFICIAL MAY REQUIRE EXPLOR
 ATIONS, TEST OR OTHER ADEQUATE PROOF AS
 TO THE PERMISSIBLE SAFE BEARING
 CAPACITY. REQUIRED TEST AND RECOMMENDA-
 TIONS SUBMITTED TO VERIFY BEARING CAPA-
 CITY SHALL BE CERTIFIED BY A GEOTECH-
 NICALREPORT FROM A DESIGN PROFESSIONAL
 PROPERLY LICENSED IN THE STATE OF FLORI-
 DA.PLANS, SPECIFICATIONS,REPORTS OR
 OTHER DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
 FLORIDA.
  
 11) PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 12)FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORTS,MISSING REPORTS ARE AS
 FOLLOWS:
 A) FRONT DOOR- MASONITE REPORTS ARE
 ILLEGIBLE, PROVIDE CLEAR COPIES
 B) CLOSPAY GARAGE DOOR- MISSING FLORIDA
 PRODUCT APPROVAL COVER SHEET
 C) ROOFING ASSEMBLIES-
 1) HANSON ROOF TILE INDICATE THE
 METHOD OF INSTALATION FOR THE ROOF
 PRESSURES.INDICATE HOW ATTACHMENT
 WILL OCCUR, FOAM, SCREWS OR NAIL
 TYPE, WITH OR WITHOUT CLIP.
 2) MISSING THE FL COVER SHEET.
 3) MISSING REPORTS FOR UNDERLAYMENTS.
 D) NOTHING FOR SLIDING GLASS DOORS.
 E) WINDOWS- MISSING THE FLORIDA PRODUCT
 APPROAL COVERSHEET.
 F) STRUCTURAL COMPONENTS- MISSING INFORM
 ATION FOR TRUSS ANCHORS FL APPROVAL &
 PRODUCT APPROVALS.
 G) RAILINGS- NO INFORMATION SUBMITTED.
 H) SOFFIT- ALUMINIUM NO INFORMATION
  
 13) FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,
 THERE SEEMS TO BE SOME DISCREPANCIES IN
 THE FOUNDATION AND THE RECOMENDATION OF
 THE GEOTECH ENGINEER. THE STRUCTURAL
 SHEETS INDICATE A WF-16A FOUNDATION. THE
 GEOTECH REPORT RECOMENDS THE FOUNDATION
 BE 18" BELOW FINISH GRADE AND A MINIMUM
 OF 24" WIDE, WHY WAS THE GEOTECH REPORT
 RECOMMENDATIONS NOT FOLLOWED?
 THE SECOND ISSUE WITH THE FOUNDATION
 DEALS WITH THE APPLICATION OF GYPSUM
 WALLBOARD SHEATHING, 2504.4.1 DEALS WITH
 THE APPLICATION OF EXTERIOR GYPSUM WALL-
 BOARD SHEATHING, THE GYPSUM BASE VENEER
 SHALL BE DONE WITH 2506 OR GA 216. IN GA
 216-4.6.6. GYPSUM BOARD USED IN BUILDING
 CONSTRUCTION SHALL BE NOT LESS THAN 8"
 FROM FINISH GRADE IN FULLY WEATHER AND W
 EATHER PROTECTED SIDING SYSTEMS, AND NOT
 LESS THAN 12" FROM THE GROUND WITHIN
 PROPERLY VENTED CRAWL SPACES.
 THE ADDITONAL 8" FROM THE BOTTOM OF THE
 GYPSUM BOARD TO GRADE HAS NOT BEEN ADD-
 RESSED?
  
 14)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMENT NUMBER, WITH A DESCRIPTION
 OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND, WILL HELP TO EXPE-
 DITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
 JIM WITMER CBO
 PLAN REVIEW
 (561)805-6715
 FAX: (561)659-8026
  
  
  
  
  
  
  
  
  
  
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.