| Plan Review Notes For Permit 04090291 |
| Permit Number |
04090291 |
|
| Review Stop |
P |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2004-11-19 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 11 | | | | | | FROM PREVIOUS REVIEW: | | | | | | DETAIL FOR SINK SHALL SHOW KNEE | | | CLEARANCE 11-4.24.3, SINK DEPTH | | | 11-4.24.4, - PARALLEL APPROACH STILL | | | SHOWN ON SHTS 1 AND 4. FORWARD APPROACH | | | IS REQUIRED 11-4.24.5. | | | | | | CLOUDED AREA SHT 1 SHOWS 36" WITH HAND | | | DRAWN CORRECTIONS. THIS IS NOT APPROVED | | | SECTION 104.2.1.3 | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|