| Plan Review Notes For Permit 04090017 |
| Permit Number |
04090017 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2004-11-30 00:00:00 | DENIED | | | | | | 1) THE WINDLOAD PRESSURES FOR THE | | | BREAKFAST NOOK WINDOWS ARE GIVEN ON | | | SHEET A-6 WITH THE ARROW POINTING TO | | | THE | | | WRONG LOCATION. | | | | | | 2) ON SHEET A-5 TWO DIFFERENT SETS OF | | | WINDLOAD PRESSURES ARE SPECIFIED FOR | | | THE | | | GOLF CART GARAGE DOOR. SEE FRONT AND | | | LEFT ELEVATIONS. THE NEGATIVE PRESSURE | | | GIVEN FOR THE DOOR ON THE LEFT | | | ELEVATION | | | EXCEEDS THE DESIGN PRESSURE ON THE | | | PRODUCT APPROVAL. | | | | | | 3) THE ATTIC ACCESS IN THE CEILING OF | | | HIS WALK IN CLOSET ON THE FIRST FLOOR | | | WILL NOT PROVIDE ACCESS TO THE ATTIC | | | SPACE ABOVE THE MASTER SUITE BECAUSE IT | | | IS LOCATED BELOW THE SECOND FLOOR | | | BATHROOM. AN ACCESS THROUGH THE WALL OF | | | THE SECOND FLOOR WALK IN CLOSET INTO | | | THE | | | ATTIC SPACE OF MASTER SUITE WOULD BE | | | ADEQUATE. | | | | | | 4) A LARGE PORTION OF THE SECOND FLOOR | | | IS WOOD FRAME HOWEVER THE INSTALLATON | | | SCHEDULE FOR THE STORM PANELS SPECIFIES | | | CALK-IN FASTENERS WHICH ARE NOT FOR USE | | | IN WOOD. PLEASE CORRECT. | | | | | | IF YOU HAVE QUESTIONS PLEASE CALL: | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|