Plan Review Notes
Plan Review Notes For Permit 04090017
Permit Number 04090017
Review Stop B
Sequence Number 1
Notes
Date Text
2004-10-25 00:00:00DENIED
  
 1) ONE HOUR FIRE RATED GLASS BLOCK IS
 REQUIRED ON THE ZERO LOT LINE. PLEASE
 SPECIFY THIS ON THE FLOOR PLAN.
  
 2) FBC 11-4.23.2 REQUIRES AT LEAST ONE
 FULL BATH ON THE FIRST FLOOR TO HAVE A
 DOOR WITH A 29" CLEAR OPENING.
  
 3) SPECIFY THE POSITIVE AND NEGATIVE
 WINDLOAD PRESSURES FOR THE (2) 3050
 CSMT. WINDOWS IN BEDROOM #2, THE (2)
 FRENCH DOORS WITH SIDELITES IN THE
 FAMILY ROOM AND THE (3) FIXED GLASS
 PANELS IN THE BREAKFAST NOOK.
  
 4) UPDATE THE REFERENCE TO ASCE 7-88 IN
 THE GLASS BLOCK DETAIL ON A12. IT SHOULD
 BE ASCE 7-98.
  
 5) SUBMIT THE LISTING INFORMATION AND
 SPECIFICATIONS FOR THE ONE HOUR FIRE
 RATED GLASS BLOCKS.
  
 6) THE ATTIC ACCESS SPECIFIED IN THE
 CEILING OF HIS W.I.C. ON THE FIRST FLOOR
 IS WHERE THE FLOOR TRUSSES ARE LOCATED.
 PLEASE CORRECT.
  
 7) SPECIFY ATTIC ACCESS AT THE 3-CAR
 GARAGE AND MASTER SUITE AS REQUIRED BY
 FBC 2309.6.
  
 8) THE CIRCULAR STAIRS ARE REQUIRED TO
 HAVE A MINIMUM TREAD DEPTH OF 9" WITH A
 1" NOSING MEASURED 12" FROM THE SMALLER
 RADIUS PER FBC 1007.8.3. PLEASE CLARIFY
 THIS ON THE PLANS.
  
 9) SAFETY GLAZING IS REQUIRED WITHIN 3'
 HORIZONTALLY OF BATHTUBS OR SHOWERS PER
 FBC 2405.2.1 IF LESS THAN 60" ABOVE THE
 FLOOR OR WALKING SURFACE. SPECIFY TEMP.
 GLASS AT 2ND FLOOR BATH #3 AND #4.
  
 10) ATTIC VENTS ARE ALLOWED ON THE ZERO
 LOT LINE SIDE. SEE NOTE ON A13.
  
 11) SUBMIT A KEY PLAN AND INSTALLATION
 SCHEDULE FOR THE STORM PANELS. SPECIFY
 THE MOUNT, FASTENERS AND FASTENER
 SPACING THAT WILL BE USED.
  
 12)FBC 1005.4.5 (GLITCH AMENDMENTS
 JULY 1, 2003) REQUIRES AT LEAST ONE
 MEANS OF ESCAPE FROM A DWELLING WHEN
 SHUTTERED FOR IMPACT PROTECTION. THE
 MEANS OF ESCAPE SHALL BE WITHIN THE
 FIRST FLOOR OF THE DWELLING AND CAN NOT
 BE LOCATED IN A GARAGE. OCCUPANTS IN ANY
 PART OF THE DWELLING SHALL HAVE ACCESS
 TO IT WITHOUT HAVING TO PASS THROUGH A
 LOCKABLE DOOR NOT UNDER THEIR CONTROL.
 INDICATE HOW COMPLIANCE WILL BE
 ACHIEVED.
  
 13) THE ENTRY DOORS ON A3 SPECIFIED AS
 WOOD, HOWEVER, THE PRODUCT APPROVAL
 SUBMITTED IS FOR FIBERGLASS DOORS.
 PLEASE CLARIFY.
  
 14) THE NEGATIVE PRESSURE SPECIFIED ON
 A5 FOR THE 8'X8' GARAGE DOOR IS GREATER
 THAN THE NEGATIVE DESIGN PRESSURE ON THE
 PRODUCT APPROVAL. PLEASE CORRECT.
  
 15) SPECIFY ON SHEET A3 OF THE PLANS
 THAT THE DEN IS NOT TO BE USED AS A
 SLEEPING ROOM OR PROVIDE EGRESS WINDOWS.
  
 IF YOU HAVE QUESTIONS PLEASE CALL:
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714