Plan Review Notes
Plan Review Notes For Permit 04081475
Permit Number 04081475
Review Stop P
Sequence Number 2
Notes
Date Text
2005-04-23 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
  
  
 1) TOILET ROOM IN THE WAITING AREA DOES
 NOT MEET CODE REQUIREMENTS FOR A 5'
 TURNING AREA. THE W/C CAN NOT INTRUDE
 INTO THE 5' TURNING AREA, AND TOILET
 ROOM SHALL BE ENLARGED TO ACCOMODATE
 THIS REQUIREMENT. SECTION 11-4.22.3
 2) TOILET ROOMS SHALL BE ACCESSIBLE,
 PLEASE INDICATE BY SHOWING THE FOLLOWING
 INFORMATION:
 A. CLEAR FLOOR SPACE 11-4.16.2
 B. TOILET HEIGHT 11-4.16.3
 C. GRAB BARS 11.4.16.4
 D. FLUSH CONTROLS 11-4.16.5
 E. DISPENSERS 11-4.16.6
 F. LAV HEIGHT & CLEARANCES 11-4.19.2
 G. LAV CLEAR FLOOR SPACE 11-4.19.3
 H. EXPOSED PIPES & SURFACES 11-4.19.4
 I. FAUCETS 11-4.19.5
 SUBMIT A DETAIL & SHOW CLEAR FLOOR SPACE
 ON FLOOR PLAN. ALSO SHOW CLEAR FLOOR
 SPACE FOR, (DRINKING FOUNTAIN OR WATER
 COOLER), SEE FOLLOWING COMMENT.
 3) IF A DRINKING FOUNTAIN IS TO BE
 INSTALLED, SANITARY PIPING AND WATER
 PIPING SHALL BE SHOWN. IF THIS IS A
 BOTTLED WATER COOLER THEN PIPING WILL
 NOT BE REQUIRED. PLEASE CLARIFY.
  
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]