| Plan Review Notes For Permit 04080784 |
| Permit Number |
04080784 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2004-08-24 00:00:00 | | | | BUILDING PROVISO: | | | FRENCH DOORS, 1012.1.8. A LATCH OR OTHER | | | FASTENING DEVISE ON A DOOR SHALL BE PRO- | | | VIDED WITH A RELEASING DEVISE HAVING AN | | | OBVIOUS METHOD OF OPERATION UNDER ALL | | | LIGHTING CONDITIONS. THE RELEASING MECH- | | | ANISM FOR ANY LATCH SHALL BE LOCATED AT | | | LEAST 34" AND NOT MORE THAN 48" ABOVE | | | THE FINISH FLOOR. DOORS SHALL BE OPEN- | | | ABLE WITH NOT MORE THAN ONE RELEASING | | | OPERATION (THIS INCLUDES FLUSH BOLTS). | | | | | | 1012.1.6 DOOR HANLES, PULLS, LATCHES, | | | LOCKS AND OTHER OPERATING DEVICES SHALL | | | BE OPERABLE WITH ONE HAND & SHALL NOT | | | REQUIRE GRASPING, PINCHING, OR TWISTING | | | OF THE WRIST TO OPERATE. THE FORCE RE- | | | QUIRED TO OPERATE THE CONTROLS SHALL BE | | | NO GREATER THAN 5 LBS. |
|