| Plan Review Notes For Permit 04080636 |
| Permit Number |
04080636 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2004-08-17 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04080636 | | | ADD: 622 N. FLAGLER DR. #701 | | | CONT: THE PLACE FOR TILE. INC. | | | TEL: (305)417-0213 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) THE NOTICE OF COMMENCEMENT SHALL BE | | | RECORDED AT PALM BEACH COUNTY COURTHOUSE | | | AND A COPY SUBMITTED TO THIS OFFICE | | | BEFORE A PERMIT CAN BE ISSUED.BLANK | | | FORMS ARE AVAILABLE FROM THIS OFFICE. | | | | | | 2) IF FLOORING TILE OR MARBLE IS 3/8" | | | THICK AND INSTALL WITH THINSET THAT'S | | | FINE, BUT IF THE TILE OR MARBLE IS THICK | | | ER THAN 3/8" AND DRYPACK IS USED, A | | | CERTIFIED ENGINEER HAS TO APPROVE THE | | | FLOORING DESIGN DUE TO LOAD BEARING | | | ISSUES. SEE.FBC. 1603.1 | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEW | | | TEL: (561)805-6726 | | | FAX: (561)659-8026 |
|