| Date |
Text |
| 2004-08-23 00:00:00 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | [email protected] |
| | |
| | 1.)THE OWNER ON THE APPLICATION DOES |
| | NOT MATCH THE OWNER IN OUR RECORDS. |
| | PLEASE ADDRESS. |
| | |
| | 2.)A NOTICE OF COMMENCEMENT MUST BE |
| | FILED WITH THE CLERK OF COURTS BEFORE A |
| | PERMIT CAN BE ISSUED, FS713.13. |
| | |
| | 3.)PLEASE PROVIDE A SECOND COPY OF |
| | THE ENERGY CALCS. |
| | |
| | 4.)IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY.THE PLANS MUST BE |
| | STAMPED AND THE RECEIPT ATTACHED TO THE |
| | APPLICATION. |
| | |
| | 5.)ADDITIONAL FEES DUE (VALUE |
| | INCREASE, RADON). |
| | |
| | 6.)SITE PLAN, S1 DIFFERS FROM THE |
| | SITE PLAN PREPARED BY THE SURVEYOR. |
| | |
| | 7.)SHEET C1, CALCULATIONS, GROUND |
| | FLOOR LIVE LOAD IS TO COMPLY WITH |
| | FBC TABLE 1604.1.YOU DECLARE AN |
| | OCCUPANCY OF 7 PER SF WHICH WOULD BE |
| | CONSISTENT WITH ASSEMBLY WITHOUT FIXED |
| | SEATS FBC TABLE 1003.4.SHEET C1 GIVE |
| | A LIVE LOAD FOR FLOORS OF 40.ASSEMBLY |
| | WITHOUT FIXED SEATS REQUIRES 100, FBC |
| | TABLE 1604.1.PLEASE REVISE. |
| | |
| | 8.)PROVIDE A SOILS INVESTIGATION |
| | REPORT FBC1804.2.2. |
| | |
| | 9.)PLEASE PROVIDE A DIMENSION FOR |
| | 'A' (ZONE 3 EDGE STRIP), ROOF ZONE |
| | DIAGRAM A7. |
| | |
| | 10.) 6-A6 SHOWS FLOOR TRUSSES.C1 |
| | REFERS TO 2ND FLOOR LIVE LOAD DESIGN |
| | CRITERIA.6-A6 IS USED IN AN AREA |
| | WHICH DOES NOT APPEAR TO HAVE A 2ND |
| | FLOOR, AND A 2ND FLOOR PLAN HAS NOT |
| | BEEN PROVIDED.AREA CALCS ARE FOR A |
| | FIRST FLOOR ONLY.PLEASE CLARIFY. |
| | |
| | 11.)12-A6, THE FASTENING AND |
| | ALLOWABLE LOADS CONFLICT WITH THE |
| | TECHNICAL BULLETIN.PLEASE CLARIFY. |
| | CHECK ALL CONNECTORS. |
| | |
| | 12.)THE PRE STORM PREPARATION PLAN |
| | SUBMITTED IS FOR THE CONDOMINIUM |
| | BUILDINGS. SUBMIT A PLAN FOR THE |
| | CLUBHOUSE. |
| | |
| | 13.)THE PRODUCT APPROVAL FOR THE |
| | BENCHMARK DOOR IS FOR AN OPAQUE DOOR |
| | WITH SIDELITES; PRODUCT APPROVALS FOR |
| | SLIDING GLASS DOORS AND HORIZONTAL |
| | SLIDER WINDOWS WERE SUBMITTED; NONE ON |
| | THE PLAN.PLEASE SUBMIT PRODUCT |
| | APPROVALS FOR THE MULLIONS, FRENCH |
| | DOORS, SINGLE HUNG WINDOWS, 3080 SOLID |
| | DOORS, AND ROOF. |