| Plan Review Notes For Permit 04071290 |
| Permit Number |
04071290 |
|
| Review Stop |
E |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2005-04-20 00:00:00 | ******* UNSAT ******* | | | | | | 1)NOTE: PLEASE SEE PANEL "C" IS MISSING | | | FROM PLANS. PLEASE SHOW LOCATION OF | | | PANEL "C" ON PLANS. | | | 215.5 | | | | | | 2)NOTE: PLEASE SEE RECEPT FOR WHIRLPOOL | | | TUB NOT SHOWN AS GFI/GFI PROTECTED. | | | 680.24 | | | | | | 3)NOTE: PLEASE SEE MISSING GFI ON | | | POWDER/BATHRM. 210.52D, 210.8 | | | | | | 4)NOTE: PLEASE SEE NOTE #2 ON GEN NOTES | | | MENTIONS SD'S ON KIT/BATH LIGHTING | | | CIRCUITS, HOWEVER THESE ARE REQUIRED TO | | | HAVE ARC FAULT PROTECTION PER 210.12 | | | 2002 NEC. | | | IF ON KIT/BATH LIGHTING CIRCUIT(S), | | | THESE WOULD ALSO BE REQUIRED TO BE AFCI. | | | | | | PLEASE KNOW, SINCE PLANS ARE IN FOR | | | FINAL, ALL ITEMS MUST BE CORRECT. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|