2004-08-02 00:00:00************ UNSAT ****************
  
 1 )NOTE: PLEASE LIST THE REQ'D ARC
 FAULT PROTECTED CURCUIT(S) ON PANEL
 SCHEDULE. PLEASE SEE THAT ALL "OUTLETS"
 IN BEDROOMS ARE TO BE PROTECTED ,
 INCLUDING, LTS, RECEPTS, SD'S ETC.
 PLEASE SEE NOTE MENTIONS TO WIRE SD'S
 AHEAD OF BATH/KIT LTS. ARC FAULT
 PROECTION WOULD ALSO BE REWUIRED FOR
 THOSE BRANCH CIRCUIT(S).
  
 2 )NOTE: PLEASE SEE 220.3B4.
 PLEASE SHOW ALL RECESSED LTS BASED ON
 MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT
 BE FIGURED IN W/ 3W/PER SQ FT.
 PLEASE PROVIDE FIXTURE INFORMATION ON
 LEGEND.
  
 3)NOTE: PLEASE SEE RISER INDICATES
 EQUIPMENTS GRNDS FROM METER TO MAINS.
 PLEASE SEE 250.6 ,250.24 THIS IS NOT
 PERMITTED. EQUIPMENT GRNDS ARE ONLY
 INSTALLED AFTER THE FIRST MEANS OF
 DISCONNETC.
  
 PLANS ARE COMING BACK FOR PLUMB COMMMENT
 -S PLEASE CORRECT.
  
 ONLY NOTE: FEEDERS FROM MAINS TO PANELS
 SHOWN AS 2/0'S WHICH ARE RATED FOR 200A'
 S.
  
 ONLY NOTE: PLEASE INLCUDE ANY OTHER LV
 ON PLANS.PRE-WIRE SOUND ETC.
 IF NOT ON PLANS, SEAPRATE PLANS AND
 PERMIT WILL BE REQUIRED.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]