| 2004-10-22 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 1 | | | FBC-2001 PLUMBING | | | | | | 1) SHT A8 SANITARY RISER DIAGRAM DOES | | | NOT MEET CODE REQUIREMENTS. | | | A) MASTER BATH CROSS FITTING NOT APPRO- | | | VED AT WATER CLOSET. SECTION 706.1 | | | B) SINK SHALL DISCHARGE DOWNSTREAM OF | | | THE HORIZONTAL DRY VENT FOR THE POWDER | | | ROOM. SECTION 909.1 | | | C) WASH MACHINE AND LAUNDRY SINK SHALL | | | DISCHARGE DOWNSTREAM OF THE HORIZONTAL | | | WET VENT FOR BATH #3. SECTION 909.1 | | | D) WASH MACHINE SHALL CONNECT TO THE | | | STACK BELOW THE TUB AT THE SECOND FLOOR. | | | SECTION 901.2 | | | 2) SEE ATTACHED SHEETS SHOWING EXAMPLE | | | OF RISER DIAGRAM SECTIONS THAT MEET CODE | | | REQUIREMENTS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|