| Plan Review Notes For Permit 04070616 |
| Permit Number |
04070616 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2004-08-02 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1) SANITARY RISER DIAGRAM DOES NOT MEET | | | CODE REQUIREMENTS. | | | A) KITCHEN SINK SHALL NOT DRAIN INTO | | | THE WET VENT FOR THE BATHROOM. SECTION | | | 909.1- THE KITCHEN SINK SHALL DISCHAR- | | | GE DOWNSTREAM OF THE BATHROOM FIXTURES. | | | B) THE WASH MACHINE SHALL NOT DRAIN IN- | | | TO THE WET VENT FOR THE BATHROOM. SECT- | | | ION 909.1. - THE WASH MACHINE SHALL DIS- | | | CHARGE DOWNSTREAM OF THE BATHROOM FIXTU- | | | RES. | | | C) THE BATHROOM FROM THE SECOND FLOOR | | | SHALL NOT DRAIN PAST THE KITCHEN SINK. | | | SECTION 908.3 | | | 2) ALL INFORMATION, DRAWINGS, SPECIFIC- | | | ATIONS AND ACCOMPANYING DATA SHALL BEAR | | | THE NAME AND SIGNATURE OF THE PERSON RE- | | | SPONSIBLE FOR THE DESIGN. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|