| 2004-06-24 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04061196 | | | ADD: 373 GREGORY RD | | | CONT: ROOFING TEAM INC. | | | TEL: (561)722-5527 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | BUILDING PROVISO: | | | 1507.3.8. ASPHALT SHINGLES LOW | | | SLOPE ROOFING, UNDERLAYMENT APPLICATION | | | FOR ROOF SLOPES FROM 2:12 UP TO 4:12, | | | UNDERLAYMENT SHAL BE A MINIMUM OF TWO | | | LAYERS APPLIED AS FOLLOWS: | | | 1) STARTING AT THE EAVE, A 19-INCH | | | STRIP OF UNDERLAYMENT SHALL BE APPLIED | | | PARALLEL WITH THE EAVE AND FASTENED | | | SUFFICIENTLY TO STAY IN PLACE. | | | 2) STARTING AT THE EAVE, 36-INCH-WIDE | | | STRIPS OF UNDERLAYMENT FELT SHALL BE | | | APPLIED OVER LAPPING SUCCESSIVE SHEETS | | | 19 INCHES AND FASTENED SUFFICIENTLY TO | | | STAY IN PLACE. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|