2004-07-19 00:00:00BUILDING PLAN REVIEW
 PERMIT: 04061022
 ADD: 605 N OLIVE AVE
 CONT: CATALFUMO
 TEL: (561)307-4836
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1ST REVIEW
 ACTION: DENIED
  
 1) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 2) FL BLD CODE 1804.2.2 QUESTIONABLE
 SOILS, WHERE THE BEARING CAPACITY IS
 NOT DEFINETLY KNOWN OR IS IN QUESTION.
 WHERE THE BEARING CAPACITY OF THE SOIL
 IS NOT DEFINITLY KNOWN OR IS IN QUESTION
 THE BUILDING OFFICIAL MAY REQUIRE EXPLOR
 ATIONS, TEST OR OTHER ADEQUATE PROOF AS
 TO THE PERMISSIBLE SAFE BEARING
 CAPACITY. REQUIRED TEST AND RECOMMENDA-
 TIONS SUBMITTED TO VERIFY BEARING CAPA-
 CITY SHALL BE CERTIFIED BY A GEOTECH-
 NICALREPORT FROM A DESIGN PROFESSIONAL
 PROPERLY LICENSED IN THE STATE OF
 FLORIDA.
  
 3)FBC 13-103.1.2 BEFORE A BUILDING
 PERMIT CAN BE ISSUED, THE SUBMITTED
 ENERGY CODE COMPLIANCE FORMS SHALL BE
 SIGNED BY THE BUILDING OWNER, THE
 OWNER'S ARCHETECT OR OTHER AUTHORIZED
 AGENT LEGALLY DESIGNATED BY THE OWNER.
  
 4) SHEET T-2 ACCESSIBILITY NOTES:
 #8 WHEN THERE IS NO EDGE TREATMENT THE
 MAXIMUM CHANGE IN GRADE IS 1/4". WHEN
 CHANGE IN GRADE BETWEEN 1/4" AND 1/2"
 A BEVEL MAY BE USED WITH THE SLOPE NO
 GREATER THAN 1:2(11-4.5.2)
  
 5) SHEET T-2 ACCESSIBILITY NOTES:
 #9 CORRECT WIDTH TO BE 12'-0" (11-4.6.3)
  
 6) SHEET T-2 ACCESSIBILTY NOTES:
 #4 ACCESSIBLE ROUTE IF PART OF A MEANS
 OF EGRESS, 44" ALSO SEE (11-4.6.2(1)
 ALL PARKING SPACES MUST BE LOCATED ON AN
 ACCESSIBILE ROUTE NO LESS THAN 44".
  
 7) CORRET SHEET A-0.1 HURRICANE CRITERIA
 THE CITY OF WEST PALM BEACH IS NOT LOCA-
 TED IN A HIGH VELOCITY HURRICANE ZONE.
  
 8) F102.2.7 FIRE DISTRICT, STRUCTURE IS
 LOCATED IN A FIRE DISTRICT.ARCHITECTURAL
 TRIM ON BUILDINGS LOCATED IN THE FIRE
 DISTRICT SHALL BE CONSTRUCTED OF APPROV-
 ED NONCOMBUSTIBLE MATERIALS OR FIRE
 RETARDANT TREATED WOOD.
 SEE SHEET A-4.1 SECTION 2, FACTORY
 HARD COATED FOAM "PECKY CYPRESS BEAMS".
 SEE SHEET A-4.5 SECTIONS 1,2& 3 THE
 FAUX PECKY CYPRESS BRACKETS.
  
 9) SEE SHEET A-1.1/A-3.1 ATM RAMP IS
 MISSING THE REQUIRED 5'-0" TOP LANDING.
 11-4.8.4.(2) LANDINGS. ALL LANDINGS
 ON RAMPS SHALL NOT BE LESS THAN 60"
 CLEAR, & THE BOTTOM OF EACH RAMP SHALL
 HAVE NOT LESS THAN 72" OF STRAIGHT &
 LEVEL CLEARENCE.
  
 10)11.4.8.5. HANDRAILS: IF A RAMP HAS
 A RISE GREATER THAN 6" OR A HORIZONTAL
 PROJECTION GREATER THAN 72", THEN IT
 SHALL HAVE HANDRAILS ON BOTH SIDES.
  
 11) THIS SAME DETAIL, COLUMN AND BASE,
 IS A MEANS OF EGRESS FOR THE ATM,
 11-4.3.3. IF A PERSON IN A WHEELCHAIR
 MUST MAKE A TURN AROUND AN OBSTRUCTION,
 THE MINIMUM CLEAR WIDTH OF THE ACCESS-
 IBLE ROUTE SHALL BE AS SHOWN IN
 FIGURE 7(A) AND (B).
  
 12)S-3 DETAIL# 5, INDICATES THE USE
 PLYWOOD SHEATHING, "FIRE DISTRICT" NO
 TYPE VI CONSTRUCTION ALLOWED. PLANS
 INDICATE TYPE V BUILDING.
  
 13) A-01 BUILDING DATA INDICATES THIS
 BUILDING WILL BE BOTH "1 HR PROTECTED"
 AND "FIRE SPRINKLERED". NO INFORMATION
 HAS BEEN PROVIDED, PLEASE SUBMIT.
  
 14)FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORTS,MISSING REPORTS ARE AS
 FOLLOWS:
 A) WINDOWS
 B) EXTERIOR DOORS
 C) MULLIONS
 D) STORM SHUTTERS
 E) ROOFING ASSEMBLIES
 F) TRUSS ANCHORS
 G) EFIS SYSTEMS
  
 15) PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 16) STURCTURAL PLANS DO NOT PROVIDE
 THE WINDOW NOR DOOR BUCK ATTACHMENT.
 1606.4.4 ANCHOR METHODS. PROVIDE
 INFORMATION FOR INSTALLATION OF DOOR
 AND WINDOW BUCKS.
  
 17) 1707.4.4.1 ANCHOR REQUIREMENTS:
 WINDOW & DOOR ASSEMBLIES SHALL BE ANCHOR
 ED IN ACCORDANCE WITH THE PUBLISHED
 MANUFACTURER'S RECOMMENDATIONS TO
 ACHIEVE THEDESIGN PRESSURE SPECIFIED.
 SUBSTITUTE ANCHORING SYSTEM USED FOR
 THE SUBSTRATE NOT SPECIFIED BY THE
 FENESTRATION MANUFACTURER SHALL PROVIDE
 EQUAL OR GREATER ANCHORING AS DEMONSTRA-
 TED BY ACCEPTED ENGINEERING PRACTICES.
  
 18)1707.4.4.2 TAPERED BUCKS:
 SHALL EXTEND BEYOND THE INTERIOR FACE
 OF THE WINDOW OR DOOR FRAME SUCH THAT
 FULL SUPPORT OF THE FRAME IS SUPPORTED.
  
 19) 1707.4.5.1 MULLIONS OCCURRING
 BETWEEN INDIVIDUAL WINDOW AND GLASS
 DOOR ASSEMBLIES. TESTING REPORTS ARE
 REQUIRED BY AN APPROVED TESTING
 LABORATORY OR BE ENGINEERED.
  
 20) 1707.4.5.2 MULLIONS SHALL BE DESIGN-
 ED TO TRANSFER THE DESIGN PRESSURE LOADS
 APPLIED BY THE WINDOW OR DOOR ASSEMBLIES
 TO THE ROUGH OPENING SUBTRATE.
  
 21) SHEET A-6.1 ROOFING DETAILS AND
 SHEET S-3 INDICATE THE METAL STANDING
 SEAM ROOFING ATTACHED DIRECTLY TO THE
 METAL DECK, PROVIDE THE PRODUCT TESTING
 REPORT WITH THIS TYPE OF TESTING.
  
 22) S-3 DOOR AND WINDOW SCHEDULE HAS
 NO IDENTIFYING MARKS?
  
 23) ARCHITECTURAL & STRUCURAL BOTH INDIC
 ATE THIS STRUCTURE IS DESIGNED AS A "C"
 EXPOSURE, THE PRODUCT TESTING REPORTS
 WILL REQUIRE THE HIGHER WIND PRESSURES
 AS INDICATED IN THE WINDOW AND DOOR
 SCHEDULE.
  
 24)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 JIM WITMER
 BUILDING PLAN REVIEW
 TEL: (561)805-6715
 FAX: (561)659-8026