| Date |
Text |
| 2004-08-04 00:00:00 | DENIED |
| | |
| | 1) A RECORDED COPY OF THE NOTICE OF |
| | COMMENCEMENT MUST BE SUBMITTED BEFORE A |
| | PERMIT CAN BE ISSUED. |
| | |
| | 2) NEW PLANS NEED TO BE RESTAMPED BY |
| | THE CITY HISTORIC PRESERVATION DEPT. |
| | |
| | 3)PRODUCT APPROVALS SUBMITTED WITH |
| | PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| | ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| | PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| | PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| | STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A COVER SHEET THAT LISTS |
| | THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. IF THE PRODUCT DOES NOT HAVE |
| | STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| | TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| | SPECIFIC FORM PER RULE 9B-72. |
| | SUBMIT THE FLORIDA PRODUCT IDENTITY |
| | NUMBER FOR WINDOWS, DOORS, ROOFING, AND |
| | OTHER STRUCTURAL ITEMS LISTED IN RULE |
| | 9B-72. |
| | |
| | 4)THE PLANS SPECIFY ALL EXTERIOR GLAZING |
| | TO BE IMPACT RESISTANT. THE PRODUCT |
| | INFORMATION THAT WAS SUBMITTED IS FOR |
| | NON IMPACT RATED. PLEASE CORRECT. |
| | |
| | 5) SUBMIT A KEY PLAN AND INSTALLATION |
| | SCHEDULE FOR THE STORM PANELS IN |
| | ADDITION TO THE STATE PRODUCT APPROVAL, |
| | IF GLAZING IS NOT IMPACT RESISTANT. |
| | |
| | 6) SUBMIT STATE PRODUCT APPROVALS FOR |
| | THE FOLLOWING: |
| | - GLAZED DOUBLE AND SINGLE FRENCH DOORS |
| | (IMPACT RATED) |
| | - GLAZED DOUBLE OUTSWING DOORS WITH |
| | SIDELITES (IMPACT RATED) |
| | - SINGLE OUTSWING FIBERGLASS OR STEEL |
| | DOOR AT GARAGE (IMPACT RATED) |
| | - CASEMENT WINDOWS (IMPACT RATED) |
| | - STRUCTURAL MULLIONS (IMPACT RATED) |
| | - SINGLE OUTSWING ENTRY DOOR "PEC. WOOD" |
| | (IMPACT RATED) |
| | |
| | 7) THE ENERGY CALCULATION FORMS SPECIFY |
| | A CEILING FAN CREDIT. THE PLANS DO NOT |
| | INDICATE ANY CEILING FANS IN THE FAMILY |
| | ROOM. THE FBC CHAPTER 13-607.1A.1 |
| | REQUIRES 2 FANS (MINIMUM OF 48" EACH) IN |
| | THIS ROOM. |
| | |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |
| | (561)805-6714 |