| Date |
Text |
| 2004-07-02 00:00:00 | DENIED |
| | 1. THE NOTICE OF COMMENCEMENT SHALL BE |
| | RECORDED AT PALM BEACH COUNTY |
| | COURTHOUSEAND A COPY SUBMITTED TO THIS |
| | OFFICE |
| | BEFORE A PERMIT CAN BE ISSUED.BLANK |
| | FORMS ARE AVAILABLE FROM THIS OFFICE. |
| | |
| | 2.BASED ON SBCCI BUILDING VALUATION |
| | DATA THE VALUATION HAS BEEN ADJUSTED TO |
| | $469,619.ADDITIONAL PERMIT FES ARE DUE |
| | |
| | 3.SMOKE DETECTORS ARE REQUIRED IN BOTH |
| | MAIN HOUSE AND GUEST COTTAGE. SEE |
| | ELECTRICAL REVIEW NOTES. |
| | |
| | 4.PRODUCT APPROVAL MISSING FOR |
| | PLYCRAFT GARAGE DOORS.SUBMIT 2 COPIES. |
| | ALSO PLYCRAFT NOT LISTED ON DCA |
| | PRODUCT APPROVAL SITE. |
| | PRODUCT APPROVALS SUBMITTED WITH |
| | PERMIT APPLICATION AFTER OCTOBER 1, |
| | 2003ARE REQUIRED TO COMPLY WITH THE |
| | FLORIDA PRODUCT APPROVAL SYSTEM. FOR |
| | INFORMATIONPLEASE SEE THE STATE WEBSITE |
| | AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| | STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A COVER SHEET THAT LISTS |
| | THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. IF THE PRODUCT DOES NOT HAVE |
| | STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| | TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| | SPECIFIC FORM PER RULE 9B-72. SEE |
| | ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| | |
| | 5. SUBMIT SECOND FLOOR RAILING DETAIL. |
| | 1015.2 HEIGHT. GUARDRAILS SHALL |
| | FORM A VERTICAL PROTECTIVE BARRIER NOT |
| | LESS THAN 42" HIGH. |
| | 1015.3 OPENINGS. OPEN GUARDRAILS |
| | SHALL HAVE INTERMEDIATE RAILS OR ORNA- |
| | MENTAL PATTERNS SUCH AS A 4" DIAMETER |
| | SPHERE CAN NOT PASS THROUGH. A BOTTOM |
| | RAIL OR CURB SHALL BE PROVIDED THAT |
| | WILLREJECT THE PASSAGE OF 2" DIAMETER |
| | SPHERE. |
| | |
| | 6.SHOW LOCATION AND SIZE OF ATTIC |
| | ACCESS COPLYING WITH FBC 2309.6. |
| | |
| | 7.TRUSS PLANS NOT REQUIRED FOR REVIEW. |
| | PLEASE REMOVE FROM PLAN PACKAGE. |
| | |
| | 8.PAGE A6 IS 16TH" SCALE. WPB |
| | AMMENDMENTS TO THE FBC SEC104.2.1.3 |
| | MIN 1/8" SCALE REQUIRED. |
| | |
| | 9.SUBMIT PRODUCT APPROVAL FOR SIMPSON |
| | STRAPS AND SHOW SCHEDULE ON PLAN. |
| | |
| | 10.SECOND FLOOR DOOR ON GUEST COTTAGE |
| | TO STAIRS SHALL COMPLY WITH 1012.1.3#3 |
| | |
| | 11.PLEASE SUBMIT 2ND COPY OF SOIL |
| | REPORT. |
| | |
| | ANY QUESTIONS CALL ME. |
| | |
| | ART LANGE |
| | BUILDING PLANS EXAMINER |
| | 805-6672 |
| 2004-06-22 00:00:00 | MUST PULL A SEPARATE PERMIT FOR POOL. |