| 2004-06-24 00:00:00 | *********** UNSAT *************** |
| | BLDG #8 |
| | |
| | 1)NOTE: PLEASE SHOW ALL CIRCUITING ON |
| | PLANS AND CORRELATE WITH THE SUBMITTED |
| | PANEL SCHEDULE. |
| | |
| | 2)NOTE: PLEASE SEE FS 471.023 AND FAC |
| | 61G15-23.002. PLEASE INCLUDE REQUIRED |
| | LICENSE #'S ON TITLE BLOCK. |
| | PLEASE SEE FIRM AS SHOWN ON PLAN IS |
| | SHOWN AS LICENSE "CLOSED" ON STATE |
| | DBPR. PLEASE SEE PRINT OUT ATTACHED. |
| | PLEASE SEE # WAS NOT ON TITLE BLOCK. |
| | PLEASE ALSO SEE THIS IS REQUIRED ON |
| | ALL SHEETS AND FOR ALL TRADES WHEATHER |
| | OR NOT COMMENT IS MADE BY OTHER REVIEWER |
| | -S. |
| | |
| | 3)NOTE: PLEASE SHOW/ INDICATE A/C CU |
| | DISC PER 440.11 |
| | |
| | 4)NOTE: PLEASE SEE 410.8 FOR FIXTURE |
| | TYPE AND CLEARENCE FOR MASTER CLOSET. |
| | DOES NOTE SEEM TO MEET 410.8 |
| | |
| | 5)NOTE: PLEASE SEE OCP SHOWN FOR AHU |
| | IS MUCH LARGER THAN OCP FOR CU, YET |
| | LOAD CALCS SHOW CU LOAD?? |
| | PLEASE CORRELATE WITH MECH PLANS. |
| | |
| | 6)NOTE: PLEASE SEE MISPRINT FOR 210.12 |
| | ON E-8 |
| | |
| | 7)NOTE: PLEASE SEE NFPA-72FOR SD |
| | LOCATIONS. 3' FROM BATHS/KITCHENS AND |
| | 20' FROM COOKING APPLIANCES. W/ EXCEPT- |
| | -IONS. |
| | |
| | PLEASE SEE COMMENTS FROM OTHER REVIEWERS |
| | AS THEY MAY HAVE AN AFFECT ON ELECTRICAL |
| | PLANS. |
| | |
| | PLEASE SUBMIT THE ABOVE INFORMATION FOR |
| | REVIEW. IF THERE ARE ANY QUESTIONS, |
| | PLEASE DO NOT HESITATE TO CALL. |
| | |
| | DEWEY PALMER |
| | ELECTRICAL PLAN REVIEW |
| | CITY OF WEST PALM BEACH |
| | CONSTUCTION SERVICES DEPT. |
| | 561-805-6717 |
| | [email protected] |