2004-06-24 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
  
 1) SHT 3 DEMO NOTES AT TOP OF SHEET #5
 STATES REMOVE EXISTING SHOWER ENCLOSURE.
 NO SHOWER ENCLOSURE IS SHOWN IN BATH #2.
 PLEASE CLARIFY. SECTION 104.2.1
 2) ALL CAPPED PLUMBING PIPES SHALL BE
 INSPECTED PRIOR TO COVERING. (ADD TO THE
 NOTES). SECTION 104.2.1
 3) SHT 4 PARTIAL SANITARY RISER DIAGRAM,
 THE NEW TUB IS SHOWN AS AN "S" TRAP AND
 NOT APPROVED INSTALLED AS SUCH. SECTION
 1002.3(5).
  
 REVIEW BY KEN STEVENS
 (561) 805-6721