2004-06-25 00:00:001ST REVIEW
 ACTION: DENIED
  
 1) PLANS SHALL BE SIGNED,SEALED,DATED
 BY A CERTIFED LICENSE PROFESSIONAL
 FS481.229(1)(C)
  
 2) SHEET #1 PLEASE INDICATE CLEARLY
 WHICH WALLS WILL BE DEMOED
  
 3) SHEET #3 FIRE PLACE: PLEASE INDICATE
 ON PLANS WHERE IT WILL BE LOCATED. AND
 SUBMIT DETAILS OF CONSTRUCTION AND
 MATERIALS TOBE USED. ALSO THE RECESS
 LIVING ROOM, THERE IS NO INFORMATION
 OR DETAILS OF THE CONSTRUCTION PLEASE
 SUBMIT A DETAIL /ENGINEERED DRAWING OF
 THIS RECESS FLOOR.
  
 4) SHEET #3 : STATES SOFFIT CHANGES
 LIVING ROOM ONLY BUT THIS IS NOT CLEARLY
 STATED. GIVE DETAILS OF THE MATERIALS
 TO BE USED,DIMENTIONS,FASTENERS AND
 ATTATCHMENT INFORMATION.
  
 5) SHEET #7: NEEDS CONSTRUCTION INFO.
 HOW IS THIS CEILING GOING TO BE
 CONSTRUCTED? STATE MATERIALS TO BE USED
 SPACING OF WOOD OR METAL STRUCTURE ETC.
  
 6)FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,
 SHEET #11 CEILING PLAN.WHAT TYPE OF
 MATERIALS WILL BE USED TO SUPPORT
 CEILING? ALSO GIVE FASTENING DETAILS.
  
 7) SHEET#4: IF FLOOR TILE/MARBLE IS 3/8"
 OR LESS THICK AND IS INSTALLED USING
 THINSET,LOAD MAY NOT BE A PROBLEM.
 HOWEVER IF THE THICKNESS IS MORE THAN
 3/8" AND INSTALL USING DRYPACK A
 CERTIFIED LICENSED ENGINEER HAS TO
 APROVE THE DESIGN LOAD.FBC1603.1
  
  